NYC-WTC_000048996
Calibration data for GCMS analysis of volatile organic compounds recorded on April 23, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Calibration report detailing response factors for multiple analytes used in the analysis of sample AE08839.
NYC-WTC_000049311–000049314Folder label: “GCMS X 4/15/02 A 4/24/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\APR2 3 02\CAL80.D Vial: 2 Acq On 23 Apr 2002 3:21 pm Operator : Sample Inst : 209 Mise : Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Apr 24 8:08 2002 Quant Results File: GCMS0412.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0412.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed Apr 17 11:48:30 2002 Response via : Initial Calibration DataAcq Meth : GCMS0412
Compound R.T. Qlon Response Cone Unit Qvalue 33) Hexachlorobenzene 24.70 284 732095 85.22 ug/1 95 3 4) Phenanthrene 25.67 178 3058868 79.19 ug/1 100 35) Anthracene 25.81 178 3025727 79.64 ug/1 100 36) Di-n-butylphthalate 27.57 149 3700996 76.59 ug/1 100 3 7) Fluoranthene 29.30 202 3086263 79.43 ug/1 95 4 0) Pyrene 29.98 202 3109631 78.21 ug/1 94 41) Butylbenzylphthalate 32.10 149 1410787 72.56 ug/1 95 42) Benzo(a)anthracene 33.60 228 2196802 79.65 ug/1 100 43) Bis(2-ethylhexyl)phthalate 33.87 149 1702408 68.43 ug/1 99 44) Chrysene 33.74 228 2150614 78.63 ug/1 100 46) Di-n-Octylphthalate 35.61 149 2517865 71.93 ug/1 # 99 47) Benzo(b)fluoranthene 36.71 252 1885457 83.37 ug/1 98 48) Benzo(k)fluoranthene 36.79 252 1813475 82.34 ug/1 98 4 9) Benzo(a)pyrene 37.70 252 1571168 84.26 ug/1 99 50) Indeno(1,2,3-cd) pyrene 41.99 276 1434277m 76.40 ug/1 51) Dibenz(a,h)anthracene 42.07 278 1112346 77.70 ug/1 96 52) Benzo(g,h,i)perylene 43.23 276 1123079 71.66 ug/1 97
(#) = qualifier out of range (m) = manual integration CAL80.D GCMS0412.M Wed Apr 24 08:09:09 2002 Page 2
NYC-WTC_000049313
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000048996
Calibration data for GCMS analysis of volatile organic compounds recorded on April 23, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000048705
Calibration report for DFTPP standard used in GCMS analysis, generated on April 15, 2002, by operator.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000048890
GCMS calibration data report for sample AE08684 analyzed on April 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000049405
Calibration report detailing response factors for multiple analytes used in the analysis of sample AE08971.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046468
Laboratory report displaying GCMS calibration data for sample AE09095 conducted on April 23, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000048488
GCMS calibration analysis showing quantitative results for organic compounds on April 15, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000047967
GCMS calibration results for volatile organic compounds from sample AE08209 analyzed in April 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060698
Calibration report for GCMS analysis listing response factors and detection limits for various organic compounds.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059599
Laboratory report showing GCMS blank analysis results for sample AE05847 conducted on April 16, 2002, with compound detection limits.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043340
Calibration verification records for gas chromatography-mass spectrometry analysis of volatile organic compounds.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044253
Calibration report listing quantified values for various organic compounds including nitrosamines and chlorobenzenes used for instrument verification.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039441
Calibration report for GCMS analysis of sample AE06430 conducted on April 17, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000049299
Department of Environmental Protection GCMS analysis record dated April 15-24, 2002.
Filed in the same folder
NYC-WTC_000049300
Chromatogram and calibration table for DFTPP standard used in GCMS analysis on April 23, 2002.
Filed in the same folder
NYC-WTC_000049302
Laboratory report showing blank analysis results for sample AE08839 with various compounds below detection limits.
Filed in the same folder
NYC-WTC_000049315
Reference report listing retention times and response factors for analytes in sample AE08839 analysis.
Filed in the same folder
NYC-WTC_000049320
Laboratory report documenting GCMS analysis of sample AE08840 conducted on April 26, 2002.
Filed in the same folder