NYC-WTC_000046332
Laboratory report showing GCMS calibration data for sample AE09587 generated on May 4-6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report showing GCMS calibration data for sample AE09585 generated on May 4-6, 2002.
NYC-WTC_000046294–000046302Folder label: “GCMS X 5/7/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Area Percent Report
Data File C:\HPCHEM\l\DATA\MAY0302\9585.D Vial: 12 Acq On 4 May 2002 12:49 am Operator: Sample GC/MS SCAN 4/24 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC
peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 8.156 336 340 346 rBV 412898 818261 23.13% 4.582% 2 8.229 346 348 372 rVB 43405 153848 4.35% 0.862% 3 12.188 775 780 797 rVB 1118814 2562887 72.45% 14.353% 4 14.791 1059 1064 1070 rVB 140056 280963 7.94% 1.573% 5 15.826 1171 1177 1187 rBV 1611639 3233291 91.40% 18.107%
6 21.132 1749 1756 1767 rBV 1716215 3537514 100.00% 19.811% 7 23.276 1982 1990 1997 rVB 132224 270752 7.65% 1.516% 8 25.576 2234 2241 2251 rBV2 1525990 3212702 90.82% 17.992% 9 33.640 3114 3121 3135 rBV2 932542 2151908 60.83% 12.051% 10 37.864 3573 3582 3599 rBV2 547030 1634568 46.21% 9.154%
Sum of corrected areas: 17856694
9585 .D GCMS0501.M Mon May 06 10:50:40 2002
NYC-WTC_000046297
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000046332
Laboratory report showing GCMS calibration data for sample AE09587 generated on May 4-6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046313
Laboratory report showing GCMS calibration data for sample AE09586 generated on May 4-6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046276
Laboratory report showing GCMS calibration data for sample AE09580 generated on May 3-6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045490
Technical document displaying GCMS calibration data and compound retention times for sample AE09448 processed in early May 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045472
Technical document displaying GCMS calibration data and compound retention times for sample AE09447 processed in early May 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045452
Technical document displaying GCMS calibration data and compound retention times for sample AE09391 processed in early May 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022930
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023055
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023195
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013117
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000046213
Department of Environmental Protection GCMS analysis record for the World Trade Center site dated May 7-9 2002.
Filed in the same folder
NYC-WTC_000046214
Single page excerpt from a GCMS laboratory record file stored in DEP Box 25, dated between May 7 and May 9, 2002.
Filed in the same folder
NYC-WTC_000046217
Laboratory data sheet recording GCMS blank analysis parameters for sample AE09579 conducted on May 8, 2002.
Filed in the same folder
NYC-WTC_000046226
Laboratory report of GCMS calibration analysis for sample AE09579 conducted on May 8, 2002, listing detection limits.
Filed in the same folder
NYC-WTC_000046230
Laboratory report of GCMS reference analysis for sample AE09579 conducted on May 8, 2002, showing response factors.
Filed in the same folder