NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
NYC-WTC_000035195–000035228Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report
Data File C: \HPCHEM\ 1 \DATA\DEC04 0 1\28689.D Vial: 14 Acq On '5 Dec 2001 1:04 am Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L
Peak Number 2 Butyl hexadecanoate Concentration Rank 1
R.T. EstConc Area Relative to ISTD R.T.
29.44 5.79 ug/1 1139090 Chrysene-dl2 33.03
Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 Butyl hexadecanoate 312 C20H40O2 000000-00-0 35 2 1-Hexene, 2-methyl- 98 C7H14 006094-02-6 27 3 Cyclobutane, 1,l-dimethyl-2-octyl- 196 C14H28 062338-30-1 27 4 1,3-Hexanediol, 2-ethyl- 146 C8H18O2 000094-96-2 23 Abundance / “ ......... Scan 2657 (29.436 min): 28689.D (-) 56 m/ z 56.00 100.00%l
5000 41 73 257 .... — 1 1 l ■ '
—TT "t —JLA”l0‘116110143157171185199213..228 312 29.20 29.40 29.60 29.80 ; 1 283 TTI‘"t‘1uh TT m/z 57.00 48.88% miz-> 20 40 60__ 80 100 120 140 160 180 200 220 240 260 280 300 Abundance #44549: Butyl hexadecanoate 55
5000 258 312 W f TE"T 1 i 1 1 29.20 29.40 29.60 29.80 73 240 11612® m/z 41.0.5 40.42% | 101 | 157 171 185 p-TT-r-p-T-T! j TT-T-r-|-rT*TTT->-r^ 214 I 1 1 1 'I । ' ‘ | H TT m/z->__ 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Abundance #1354: 1 -Hexene. 2-methyl- 56 -IP 41 29.20 29.40 29.60 29.80 5000 m/z 43.0.0 40.07 27
I' “ ' i'11 ■i ■ 78398........ miz-> 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Abundance #21985: Cyclobutane, 1.1 -dimethyl-2-octyl- 56 29.20 29.40 29.60 29.80 m/z 73.00 31.31% I 5000
! 27 * ..... ........ TTT 70 83 97 111 125 140 168 196_______________ 7TTTT1 . TT p I I I I i t I 1 | H . . | . . t i | ■ ■ . . { > ■ ■ . | | I | . . . I | | M i I i > > i I ------- miz-> 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 29.20 29.40 29.60 29.80
28689.D GCMS1126.M Mon Dec 10 10:19:03 2001 Page 2
NYC-WTC_000035203
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000018546
Laboratory report showing GC/MS calibration data for polycyclic aromatic hydrocarbons and deuterated standards.
1 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088456
Laboratory report documenting GC/MS analysis of environmental sample AD23272 conducted on October 15, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088000
Laboratory report documenting GC/MS analysis of sample AD23124 conducted on October 12, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder