NYC-WTC_000014807
Calibration data for sample AE11284 analyzed using Method 508 on May 17, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Calibration table and internal standard data for sample AE12095 analyzed on May 31, 2002.
NYC-WTC_000014825–000014835Folder label: “GCMS X 5/29/02 A 5/30/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File : C:\HPCHEM\1\DATA\MAY3002\12096.D vial: 15 Acq On : 31 May 2002 3:50 am Operator: Morgan Sample : re-ext Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P 2*.* Quant Method : C:\HPCHEM\1\METHODS\GCMS0520 .M (RTE Integrator) -= Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 1 2-Pentanone, 4-hydroxy-4-methy Concentration Rank 1 R.T. EstConc Area Relative to ISTD R.T. 8.07 0.93 ug/1 71002 1,4-Dichlorobenzene-d4 12.07 Hit# of 5 Tentative ID MW MolForm CAS# Qual 1 2-Pentanone, 4-hydroxy-4-methyl - 116 C6H12O2 000123-42-2 59 2 5-Hexen-2-one 98 C6H10O 000109-49-9 9 3 Acettone 58 C3H60 000067-64-1 7 4 2-Propanone, 1-cyclopropyl-______ 98 C6H10O 004160-75-2 5 Abundance Scan 329 (8.068 min): 12096.D (-) m/z 42.90 100.00% 43
5000 59
51 83 101 7.80 8.00 8.20 840’1 mRRH m/z 59.00 47.82% miz—> 5 10 15 20253035404550556065 70 75 80859095 100105 Abundance #64274:2-Pentanone, 4-hydroxy-4-methyl- 43
5000 59 7.80i 8.00 8.20 8.40 m/z 58.001 19.46% 27 ।>. <.,...111... ।. 1111li । ij n 111il +49+ 83 101 J.... |.... ।.... ।... . ।.. I. ।. ... ।.... (.. 1., I ni 1111111 miz—> 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100105 Abundance #63205:5-Hexen-2-one 43 1 i • » 7.80 8.00 8.20 8.40 5000 m/z 101.05 17.55%
27 55 15 2. I I 38,. 50 . 83 98 11111।111 [ ।, u 11 u 111I11 (TTIt 11 n 11II I1 u 111111i I, (i 11iii [ 111i1111 ipi 111111 rpi i11111111iI111,i111। n 11 /z—> 5 10 15 2025303540 45 50556065 70 75 80859095 100105 Abundance #62326: Acetone 40 7.80 8.00 8.20 8.40 m/z 41.00 8.34% 5000
27 36 58
—A— A-AAMAMA k m/z—> 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100105 7.80 8.00 8.20 8.40
12096.D GCMS0520.M Fri May 31 11:34:55 2002 Page 1
NYC-WTC_000014832
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000014807
Calibration data for sample AE11284 analyzed using Method 508 on May 17, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014843
GCMS laboratory analysis report for sample AE12097 showing unknown compounds and surrogate recovery data from June 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014771
Calibration table data for GCMS analysis including internal standards and response factors from May 31, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014754
Reference standard report for GCMS analysis of volatile organic compounds conducted on May 30-31, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014976
GCMS laboratory analysis report for sample AE12094 showing unknown compounds and surrogate recovery data from June 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013853
GCMS analysis results for sample AE12170 dated June 3, 2002, documenting unknown compounds and surrogate recovery.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013740
Report documenting analysis for unknown compounds and surrogate recovery in sample AE12281.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013751
Report documenting analysis for unknown compounds and surrogate recovery in sample AE12282.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013795
GCMS analysis results for sample AE12163 dated June 3, 2002, showing surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014912
Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE12575 conducted on June 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013843
GCMS analysis results for sample AE12169 dated June 3, 2002, documenting unknown compounds and surrogate recovery.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000015016
Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE12675 conducted on June 6, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000015027
Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE12677 conducted on June 6, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014843
GCMS laboratory analysis report for sample AE12097 showing unknown compounds and surrogate recovery data from June 4, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013369
Analytical report for sample AE12156 detailing GCMS results and surrogate recovery data from June 6, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014771
Calibration table data for GCMS analysis including internal standards and response factors from May 31, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014934
Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE12577 conducted on June 6, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014902
Gas chromatography-mass spectrometry analysis report for sample AE12151, completed on 6/6/02 at 14:58, testing for unknown compounds and 2,4-DDD surrogate.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000014729
Laboratory report documenting GCMS analysis of sample AE12574 conducted on June 7, 2002, including surrogate recovery data.
Filed in the same folder
NYC-WTC_000014730
Header page from a GCMS method document covering the period of May 29 to May 30, 2002.
Filed in the same folder
NYC-WTC_000014733
GCMS blank analysis report for sample AE12093 dated 05/31/2002 showing all measured organic compounds below minimum reporting limits (MRL) of 2.0 micrograms.
Filed in the same folder
NYC-WTC_000014742
Laboratory blank report for GCMS analysis of volatile organic compounds conducted on May 31, 2002.
Filed in the same folder
NYC-WTC_000014746
Calibration results for gas chromatography mass spectrometry analysis of volatile organic compounds from May 31, 2002.
Filed in the same folder