GCMS calibration table for TCLP method, March 2002

Machine-extracted title · confidence 100%

Instrument output displaying calibration data and surrogate recovery results for sample AE03383.

NYC-WTC_000011539–000011546

Folder label: “GCMS X 2/14/02 A 3/2/02 - 3/20/02

Page image
Scanned page image, NYC-WTC_000011542
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

LSC Area Percent Report

Data File C: \HPCHEM\ 1 \DATA\MAR0102\3383.D Vial: 47 Acq On 3 Mar 2002 9:36 am Operator: Sample gc/ms scan 2/4 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P

Method : C:\HPCHEM\1\METHODS\GCMS0208.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP

If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5

Signal : TIC

peak R.T. first max last PK peak peak peak % Of # min scan scan scan TY height area % max. total

1 8.185 338 342 361 rBV 69072 199574 4.18% 0.829% 2 12.316 786 792 808 rBV 1380002 3332470 69.81% 13.849% 3 15.961 1182 1189 1205 rBV 1977413 4453570 93.29% 18.508% 4 21.276 1761 1768 1782 rBV 2121513 4773956 100.00% 19.840% 5 25.720 2245 2252 2263 rBV2 1922882 4656552 97.54% 19.352%

6 25.857 2263 2267 2281 rVB 27120 92105 1.93% 0.383% 7 30.796 2800 2805 2814 rVB 89671 188014 3.94% 0.781% 8 33.789 3123 3131 3150 rBV2 1451332 3610166 75.62% 15.003% 9 38.067 3586 3597 3618 rBV2 808660 2756166 57.73% 11.454%

Sum of corrected areas: 24062573

3383.D GCMS0208.M Mon Mar 25 12:23:09 2002

NYC-WTC_000011542

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000011542Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →