NYC-WTC_000011707
Laboratory report of a GCMS blank run on March 27, 2002, listing target compounds and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Calibration standard analysis for sample AE00938 showing quantitative results for organic compounds.
NYC-WTC_000009566–000009569Folder label: “GCMS X 1/14/02 A 3/4/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
#
Jser: Galos, Marie Nestchester Dept. of Labs & Research Date: 03/01/2002 Time: 13:02:11 Sample: AE00938 Analysis: $C1GCMS CALI GCMS Jnits: ug Started: 3/1/02 12:58 Ended: 3/1/02 12:58 Analyst: MG age: 1
n-Nitrosodimethylamine 47.92 2.0 bis(2-Chloroethyl)ether .. 43.93’ 37.63 2.0 2.0 1,3-Dichlorobenzene 1,4-Dichlorobenzene 37.30 ” 2.0 2.0 1,2-Dichlorobenzene 36.13 2,2‘-oxybis(1-Chloropropane) 1 41.96 43.48 . 2.0 n-Nitrosodi-n-propylamine 2.0 Hexachloroethane .. 304’ 35.95 2.0 2.0 [•Nitrobenzene ! Isophorone 41.12 40.65 2.0 [ bis(2-Chloroethoxy)methane 2.0 2.0 1,2,4- T r ichlorobenzene 34.79 Naphthalene 36.34 30.10 2.0 Hexachlorobutadicne 36.80 ' 2.0 2-Chloronaphthalene 2.0 Dimethylphthalate ”37.80” 39.83 2.0 2,6-Dinitrotoluene . 2.0 2.0 'Acenaphthylene 37.75 [Acenaphthene 37.08 41.61 2.0 2,4-Dinitrotoluene 2.0 Diethylphthalate ” 36.15 2.0 4-Chlorophenylphenylether 33.88 2.0 Fluorene 35.08 2.0 Azobenzene/1,2-Diphenylhydraz 37.02 2.0 n-Nitrosodiphenylamine 35.19 2.0 4-Bromophenyiphenylether ’31.58”’ 2.0 Hexachlorobenzene ”30.69 2.0 Phenanthrene 35.68 2.0 Anthracene 35.08 2.0 2.0 Di-n-butylphthalate ’ 34.26 2.0 Fluoranthene '36.45 . 37.76 Pyrene 2.0 Butylbenzylphthalate 36.54 ’ 2.0 Benzo(a)anthracene 37.84 2.0 33.80 bis(2-Ethyhexyl)phthalate 2.0 [Chrysene 37.43 2.0 Di-n-octylphthalate 32'90 2.0 | Benzo(b)fluoranthene 36.23 2.0 Benzo(k)fluoranthene 34/92.. 2.0 Benzo(a)pyrene 38.01 2.0 2.0 [ Indeno( 1,2,3-cd)pyrene 45.03“ 43.86 Dibenz(a,h)anthracene 2.0 Benzo(g,h,i)perylene 44.75 ” 2.0.
NYC-WTC_000009566
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000011707
Laboratory report of a GCMS blank run on March 27, 2002, listing target compounds and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000012305
Laboratory report for GC/MS calibration analysis of sample AE04417 conducted on March 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009816
Calibration data for GCMS analysis including response factors for various organic compounds recorded on February 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059487
Laboratory report of a GCMS blank test conducted on April 5, 2002, showing non-detect levels for various organic compounds.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058826
Laboratory report showing GCMS calibration analysis for volatile organic compounds on April 2, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058600
Laboratory report showing GCMS blank analysis for volatile organic compounds on April 2, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058254
Calibration analysis report for sample AE04733 conducted April 1, 2002, listing concentrations of target compounds.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058360
Laboratory report showing non-detectable levels of volatile organic compounds in a method blank analyzed on March 29, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000037992
Log sheet recording sample preparation details including drip rates and pH for GCMS analysis in March 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058907
Calibration results for specific volatile organic compounds used to verify GCMS instrument performance in April 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000003568
Laboratory report listing concentrations of volatile organic compounds in sample AE01463 analyzed on February 27, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059114
Calibration results for specific volatile organic compounds used to verify GCMS instrument performance in April 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000009547
Administrative record from DEP Box 14 covering the period of January to March 2002 regarding World Trade Center environmental activities.
Filed in the same folder
NYC-WTC_000009548
Header page from a GCMS document showing surrogate recovery and pH data.
Filed in the same folder
NYC-WTC_000009554
Calibration table listing internal standards and response factors for GCMS Method 508.
Filed in the same folder
NYC-WTC_000009557
GCMS blank analysis for sample AE00938 listing compounds below detection limits.
Filed in the same folder
NYC-WTC_000009570
Reference data page listing quantitative results for volatile organic compounds.
Filed in the same folder