NYC-WTC_000003572
Reference data report for GCMS analysis of sample AE01463 conducted on February 27, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Laboratory report listing quantitative results for nitrosamines and chlorinated solvents in sample AE02581.
NYC-WTC_000005362–000005366Folder label: “GCMS X 2/5/02 A 3/7/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\MARO7O2\REF.D Vial: 16 Acq On 8 Mar 2002 4:29 am Operator: Sample gc/ms scan 2/5 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Mar 8 8:58 2002 Quant Results File: GCMS0208.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0208.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed Feb 27 11:30:15 2002 Response via : Initial Calibration DataAcq Meth : GCMS0208
Compound R.T. Qlon Response Cone Unit Qvalue
30) N-Nitrosodiphenylamine 23.26 168 61216 2.27 ug/1 # 83 31) 4-Bromophenyl-phenylether 24.35 248 42141 2.42 ug/1 93 32) Hexachlorobenzene 24.78 284 46724 2.29 ug/1 96 3 3) Phenanthrene 25.75 178 249681 3.01 ug/1 98 34) Anthracene 25.89 178 232279 2.86 ug/1 99 35) Di-n-butylphthalate 27.65 149 327904 2.83 ug/1 98 36) Fluoranthene 29.38 202 251166 3.03 ug/1 # 89 3 9) Pyrene 30.06 202 265338 2.68 ug/1 # 89 40) Butylbenzylphthalate 32.19 149 110032 2.01 ug/1 97 41) Benzo(a)anthracene 33.70 228 218007 3.01 ug/1 100 42) Bis(2-ethylhexyl)phthalate 33.97 149 181987 2.46 ug/1 96 43) Chrysene 33.83 228 238930 3.35 ug/1 99 45) Di-n-Octylphthalate 35.70 149 229781 1.70 ug/1 99 46) Benzo(b)fluoranthene 36.81 252 190595 2.50 ug/1 # 97 47) Benzo(k)fluoranthene 36.88 252 223589 2.92 ug/1 # 94 48) Benzo(a)pyrene 37.82 252 150482 2.38 ug/1 # 95 49) Indeno(1,2,3-cd)pyrene 42.18 276 170711 2.96 ug/1 # 93 50) Dibenz(a,h)anthracene 42.25 278 150252 3.41 ug/1 # 95 51) Benzo(g,h,i)perylene 43.42 276 150733 3.24 ug/1 # 93
(#) = qualifier out of range (m) = manual integration REF.D GCMS0208.M Wed Mar 13 14:21:07 2002 Page 2
NYC-WTC_000005365
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000003572
Reference data report for GCMS analysis of sample AE01463 conducted on February 27, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000006253
Laboratory results for volatile organic compounds including nitrosamines and chlorobenzenes from sample AE03385.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005247
Laboratory report detailing GCMS detection of volatile organic compounds in sample AE02595 conducted on March 4, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058604
Calibration data for GCMS analysis of volatile organic compounds recorded on April 2, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009570
Reference data page listing quantitative results for volatile organic compounds.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000038257
Laboratory report detailing GCMS analysis of sample AE03833 conducted on March 13, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000038111
Laboratory report listing detection results for volatile organic compounds in reference sample AD31498 analyzed on February 27, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000058826
Laboratory report showing GCMS calibration analysis for volatile organic compounds on April 2, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036059
Calibration report detailing response factors for standard compounds used in GCMS analysis of sample AD29135.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036345
Reference standard analysis report for GCMS testing showing concentrations of target analytes and detection limits.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035904
Document containing reference values and recovery data for organic compounds analyzed by GCMS.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000005354
Department of Environmental Protection GCMS sample tracking record for the World Trade Center site dated February to March 2002.
Filed in the same folder
NYC-WTC_000005355
Document showing laboratory parameters including drip rate and surrogates for testing procedures in DEP Box 12.
Filed in the same folder
NYC-WTC_000005358
Laboratory report listing quantitative results for nitrosamines and chlorinated solvents in sample AE02581.
Filed in the same folder
NYC-WTC_000005367
Laboratory report showing non-detectable results for nitrosamines and chlorinated solvents in GCMS blank.
Filed in the same folder
NYC-WTC_000005383
Laboratory report listing unknown compounds and surrogate recovery data for sample AE02581.
Filed in the same folder