SECTION 02082
methods developed by the USEPA and/or National Institute of Standard and Technology, which
are utilized for lower detectability and specific fiber identification.
B. Air monitoring of Contractor's personnel will be performed in conformance with OSHA
requirements. (All costs associated with this work are deemed included in the unit price.)
C. Qualifications of Testing Laboratory:
The Contractor shall employ an Industrial Hygienist or Laboratory to conduct air testing. They
shall be selected from the latest list of laboratories compiled by National Institute of Standards
and Technology (NIST SRM 1876) as having participated in the NIST Proficiency Analytical
Testing Program and been identified thereon as "Proficient" (P) in the analysis of samples for the
presence of Asbestos.
D. Contractor shall employ a qualified industrial hygiene laboratory to analyze air samples in
accordance with OSHA Regulations, 1926.1101 (Asbestos Standards for Construction), and
1910.134 (Respirator Standard) and New York City regulations. All costs for this work shall be
included in the Bid Price.
E. The industrial hygiene laboratory shall be a current proficient participant in the American
Industrial Hygiene Association (AIHA) PAT Program. The laboratory identification number
shall be submitted and approved by the City. The laboratory shall be accredited by the AIHA and
New York State department of Health Environmental Laboratory Approval Program (ELAP).
F. Industrial hygiene laboratory shall also be a current proficient participant in the NIST/NVLAP
Quality Assurance Program for the identification of bulk samples. Laboratory identification
number shall be submitted to and approved by the City.
G. Contractor shall require a competent person (as defined in OSHA 1926.1101) to perform the
following functions and to be on-site continuously for the duration of the project:
1. Monitor the set up of the Work Area enclosure and ensure its integrity.
2. Control entry and exit into the work enclosure.
3. Ensure that employees are adequately trained in the use of engineering controls, proper
work practices, proper personal protective equipment and in decontamination procedures.
4. Insure that employees use proper engineering controls, proper work practices, proper
personal protective equipment and proper decontamination procedures.
5. Competent person shall check for rips and tears in work suits, and ensure that they are
mended immediately or replaced.
H. Air monitoring responsibilities, as defined in OSHA regulation 1926.1101, shall be performed by
a representative of the testing laboratory retained by the Contractor.
I. Contractor shall submit to the City all credentials of the designated competent person and