NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Summary of asbestos Rule 56 revisions and guidance notes.
NYC-WTC_000448683–000448686OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Summary of Major Changes to Industrial Code Rule 56
Project Air Sampling ■ Asbestos Abatement Contractor independent of air monitoring firm (must be contracted separately by owner). ■ Quantity of asbestos containing material in work area determines air sampling requirements for work area. ■ Air Sampling Technician required to be on-site for duration of sample collection. ■ Asbestos Project Air Sampling Requirements - Major Changes: ♦ Air sample log requirements included. ♦ Reduced turnaround time for air sample results. ♦ Defined requirements and criteria for background air samples. ♦ Pre-abatement air samples - replaced with work area preparation samples for large project friable asbestos containing materials. ♦ Negative air exhaust - banking allowed (up to 5 exhaust tubes terminating at one common location - one sample required). ♦ Clearance for Minor Work Areas- required for incidental disturbance and if part of small or large project. ♦ Allow Transmission Electron Microscopy (TEM) instead of Phase Contrast Microscopy (PCM) for clearance. * TEM clearance - Asbestos Hazard Emergency Response Act (AHERA) protocols for clearance air sampling and analysis, unless TEM analysis of failed PCM air samples. ♦ Clarify procedures to follow for recleaning and resampling of work areas with unsatisfactory clearance air sample results.
Asbestos Survev/lnspection ■ When is a survey required and by who? ♦ Prior to Building/structure demolition, remodeling, renovation or repair for non-agricultural buildings/structures with construction commencement before 1974, unless condemned and structurally unsound. ♦ Portion of Building/structure impacted by project shall be inspected/surveyed for asbestos containing material by an asbestos contractor with appropriately certified personnel. ■ Survey Exemptions and what they mean: ♦ Not required for agricultural building. ♦ Not required for structurally unsound structure, but demolition shall be an asbestos project (as per Code Rule 56-11.5). ♦ Not required for owner of one or two-family dwelling, when the owner contracts for but does not control the demolition, renovation, remodeling or repair work. * NOTE: Survey is still required by owner’s agent. ♦ All contractors hired by the owner must still comply with OSHA and EPA, so even if no survey is required by Code Rule 56, all Presumed Asbestos Containing Materials and resilient flooring materials installed prior to 1981 are treated and handled as asbestos containing materials and are assumed to be asbestos containing materials until proven otherwise by appropriate laboratory analyses. ■ Bidding - Concurrent bidding requirements included.
Work Area Preparation ■ Asbestos Abatement Contractor Daily Project Log - summary has been added of required entries by Asbestos Abatement Contractor’s Supervisor. ■ Decontamination Units: ♦ Eliminate airlock at work area. ♦ Define Clean room minimum size. ♦ Include remote personal decontamination system enclosure, as well as when and how they may be used (some special projects, non-friables and tent with glovebag).
Page 2 of 4
CITY_21MC100_003240974
NYC-WTC_000448684
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443524
Summary explaining changes to Rule 56 for asbestos projects and guidance.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446470
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448811
New York City Part 56 asbestos documentation, NYC-WTC.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450663
City asbestos regulatory document referencing NYS Part 56; file with NYC-WTC code tag.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441450
Asbestos standards reference page from NY Department of Labor materials.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233286
Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451646
Asbestos Part 56 inspection reference document, NYC.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437549
Asbestos chain-of-custody record for NYC WTC project, including state code reference.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443524
Summary explaining changes to Rule 56 for asbestos projects and guidance.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443524
Summary explaining changes to Rule 56 for asbestos projects and guidance.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
Similar indexed content
NYC-WTC_000443524
Summary explaining changes to Rule 56 for asbestos projects and guidance.
Similar indexed content
NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
Similar indexed content
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
Similar indexed content
New York City Part 56 asbestos documentation, NYC-WTC.
Similar indexed content