NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Summary explaining changes to Rule 56 for asbestos projects and guidance.
NYC-WTC_000443524–000443527OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Summary of Major Changes to Industrial Code Rule 56
♦ Remote waste decontamination system enclosure eliminated. ♦ Small project personal decontamination system enclosure revised to 3-chambers. ■ Electric shutdown/isolation - shutdown exemption procedures included. ■ Engineering Controls: ♦ Modify negative air requirements. * Eliminate piggy-back and add use of unfiltered booster fans downstream every 25 feet from negative air unit. * Reduce 50 foot exhaust requirement to 15 foot, or if exhaust directly to exterior, then seal openings within 15 feet of exhaust location. * Exemption added for some special projects. ♦ Requirement for use of Manometer on OSHA Class I Large and Small asbestos projects. ♦ Exhaust Termination Location protected/surrounded by construction fencing (minimum of 10’ from exhaust point). ■ Barriers and Exemptions: ♦ Floor, Wall & Ceiling plastic sheeting - eliminate sheeting on removal surfaces. ♦ Negative pressure Tents: * Allowed for any quantity non-friables. * Allowed for any quantity friable thermal system insulations (TSI) w/glovebag abatement. * Allowed for minor and small quantity gross removal of friable asbestos containing material, with attached decontamination system enclosure for small quantity tent work areas. ♦ Fire-retardant Spray Plastic: * In lieu of 2 layers floor, wall and ceiling plastic sheeting. * Applied by trained personnel. ♦ Special Projects Exemptions - See Subpart 11. ♦ Removal of ceilings and components to access asbestos containing material - similar to former AV-86.
Handling ■ Pre-abatement settling period reduced to 4 hours and eliminated for exterior work where negative air ventilation is not required. ■ Sequential Abatement of multiple types of asbestos containing materials within a single regulated abatement work area is allowed as follows: ♦ Top-down abatement and most friable to least friable ♦ For example, ceiling friables (OSHA class I), then other class I friables (thermal system insulations, wall plasters) and class II friables (ceiling tile), then class II non-friables other than flooring, ending with class II non-friable flooring ♦ One complete cleaning at conclusion of each abatement type, clearance at conclusion of all abatement and cleanings ■ When is Dry Removal allowed - never according to the code...guidance issue...obtain written EPA approval first then submit for site-specific variance with EPA approval
Final Cleaning Procedures ■ Process and settling periods: ♦ Still 3 cleans, but exemption from multiple cleans when no layers or reduced layers of plastic sheeting is required, or when tent enclosure is used. ♦ Reduction in some of the settling/drying periods. ■ Visual Inspections required following final cleaning and settling/drying period. ♦ Small and Large size work area visual inspections are to be performed by project monitor hired by building owner independent of asbestos abatement contractor.
Page 3 of 4
CITY_21MC100_003243916
NYC-WTC_000443526
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448683
Summary of asbestos Rule 56 revisions and guidance notes.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446470
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448811
New York City Part 56 asbestos documentation, NYC-WTC.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450663
City asbestos regulatory document referencing NYS Part 56; file with NYC-WTC code tag.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233286
Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441450
Asbestos standards reference page from NY Department of Labor materials.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451646
Asbestos Part 56 inspection reference document, NYC.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437549
Asbestos chain-of-custody record for NYC WTC project, including state code reference.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448683
Summary of asbestos Rule 56 revisions and guidance notes.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448683
Summary of asbestos Rule 56 revisions and guidance notes.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000448496
Summary of Rule 56 revisions and guidance for asbestos regulatory updates.
Similar indexed content
NYC-WTC_000448683
Summary of asbestos Rule 56 revisions and guidance notes.
Similar indexed content
NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
Similar indexed content
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
Similar indexed content
New York City Part 56 asbestos documentation, NYC-WTC.
Similar indexed content