NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
will be included as Attachment B to the QAPP, when available.
Field Precision Objectives Field precision is assessed through the collection and
measurement of collocated and/or duplicate samples (also called field duplicates) which
consist of a second sample in addition to the original field sample. In general, field
duplicates will be collected at a frequency of once per week per analytical parameter for
the air sampling aspect of this project. Precision will be measured through the calculation
of relative percent difference (RPD). for the air sampling aspect of this project. Field
duplicates for the waste characterization purposes will be collected at a frequency of once
per every 10 samples per matrix per analytical parameter (with exception of corrosivity
and ignitibility). The resulting information will be used to assess sample homogeneity,
spatial variability at the site, sample collection reproducibility, and analytical variability.
Field duplicate RPDs must be <40 for air samples. Field duplicate RPDs must be <50 for
solid matrices and <30 for aqueous matrices for the waste characterization aspects of this
project. Field precision will be maintained by utilizing experienced/trained
sampling crews and conducting field audits. Tn addition, during the background phase of
the program, the precision of the mercury sampling and analysis method will be tested.
Ambient air samples will be collected at one location using a series of four iodated
carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the
precision of the method under actual field sampling conditions. Following the
background phase, one field spike will be performed every other week, alternating with
the field duplicates.
Laboratory Precision Objectives Precision in the laboratory is assessed through the
calculation of RPD for duplicate preparation and analyses of laboratory control samples,
or replicate injections of samples. Laboratory precision measures both sample preparation
and analysis reproducibility. Precision control limits and frequency of precision
measurements are provided in Tables 8-2 through 8-10.
8.2.2 Accuracy
Accuracy is the closeness of agreement between an observed value and an accepted
reference value. The difference between the observed value and the reference value
includes components of both systematic error (bias) and random error.
38
CITY_21MC100_003237442
NYC-WTC_000447471
OCR can misread numbers and units. Confirm readings against the page image before using them.