NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Plan for Environmental Community Air Monitoring, Greenwich/Thames

Machine-extracted title · confidence 45%

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

NYC-WTC_000440780–000440908
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Slreet/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

will be included as Attachment B to the QAPP, when available.

Field Precision Objectives Field precision is assessed through the collection and measurement of collocated and/or duplicate samples (also called field duplicates) which consist of a second sample in addition to the original field sample. In general, field duplicates will be collected at a frequency of once per week per analytical parameter for the air sampling aspect of this project. Precision will be measured through the calculation of relative percent difference (RPD). for the air sampling aspect of this project. Field duplicates for the waste characterization purposes will be collected at a frequency of once per every 10 samples per matrix per analytical parameter (with exception of corrosivity and ignitibility). The resulting information will be used to assess sample homogeneity, spatial variability at the site, sample collection reproducibility, and analytical variability. Field duplicate RPDs must be <40 for air samples. Field duplicate RPDs must be <50 for solid matrices and <30 for aqueous matrices for the waste characterization aspects of this project. Field precision will be maintained by utilizing experienced/trained sampling crews and conducting field audits. Tn addition, during the background phase of the program, the precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four iodated carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the precision of the method under actual field sampling conditions. Following the background phase, one field spike will be performed every other week, alternating with the field duplicates.

Laboratory Precision Objectives Precision in the laboratory is assessed through the calculation of RPD for duplicate preparation and analyses of laboratory control samples, or replicate injections of samples. Laboratory precision measures both sample preparation and analysis reproducibility. Precision control limits and frequency of precision measurements are provided in Tables 8-2 through 8-10.

8.2.2 Accuracy

Accuracy is the closeness of agreement between an observed value and an accepted reference value. The difference between the observed value and the reference value includes components of both systematic error (bias) and random error.

38

CITY_21MC100_003220178

NYC-WTC_000440817

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000440817Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →