Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
Tab/eS-2. Measurement Performance Cnteria Tab/e-Mets/s /CP/MS
QC Sample or Frequency Measurement Corrective DQI
Activity Performance Action
Criteria
Field l/Week *RPD < 40 Assess Precision-
Duplicates when positive laboratory Overall
results for both precision; and
samples are > /or qualify data.
5x QL
*No situation
where one
result is
detected at > 5x
QL and other
result is not
detected
Laboratory 1/prep batch RPD < 20 if Qualify data Precision-
Duplicates results are > Laboratory
5x QL
Laboratory 1/prep batch Percent Determine Accuracy/Bias
Control Sample recoveries 75- cause of
125% problem
reanalyze
and/or qualify
data.
Laboratory 1/prep batch Percent Determine Accuracy/Bias
Control Sample recoveries 75- cause of and Precision
125%RPD< problem
20 reanalyze
and/or qualify
data.
Serial Dilution 1/batch ±10% of Qualify data. Accuracy/Bias
original result
Interference 1/8 hours Percent Recalibrate and Accuracy/Bias
Check Sample recoveries 80- reanalyze
120% and/or qualify
data.
Calibration 1/10 samples Absolute value Rcclcan, Accuracy/Bias-
Sample of target metal reanalyze, Contamination
must be < QL and/or qualify
data._________
Preparation 1/prep batch Absolute value Reclean, Accuracy/Bias-
Blanks of target metal reanalyze, Contamination
must be < QL and/or qualify
39
CITY_21MC100_003237443
NYC-WTC_000447472
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000447472Source: NYC Law Department, mirrored locally