Environmental Community Air Monitoring Plan

Machine-extracted title · confidence 50%

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

NYC-WTC_000447434–000447562
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

Tab/eS-2. Measurement Performance Cnteria Tab/e-Mets/s /CP/MS QC Sample or Frequency Measurement Corrective DQI Activity Performance Action Criteria Field l/Week *RPD < 40 Assess Precision- Duplicates when positive laboratory Overall results for both precision; and samples are > /or qualify data. 5x QL *No situation where one result is detected at > 5x QL and other result is not detected Laboratory 1/prep batch RPD < 20 if Qualify data Precision- Duplicates results are > Laboratory 5x QL Laboratory 1/prep batch Percent Determine Accuracy/Bias Control Sample recoveries 75- cause of 125% problem reanalyze and/or qualify data. Laboratory 1/prep batch Percent Determine Accuracy/Bias Control Sample recoveries 75- cause of and Precision 125%RPD< problem 20 reanalyze and/or qualify data. Serial Dilution 1/batch ±10% of Qualify data. Accuracy/Bias original result Interference 1/8 hours Percent Recalibrate and Accuracy/Bias Check Sample recoveries 80- reanalyze 120% and/or qualify data. Calibration 1/10 samples Absolute value Rcclcan, Accuracy/Bias- Sample of target metal reanalyze, Contamination must be < QL and/or qualify data._________ Preparation 1/prep batch Absolute value Reclean, Accuracy/Bias- Blanks of target metal reanalyze, Contamination must be < QL and/or qualify

39

CITY_21MC100_003237443

NYC-WTC_000447472

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447472Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →