NYC 9/11 Public Portal Document
EM 1110-2-3800
1 Mar 72
(2) Advantages of electric blasting caps include safety in handling,
variety of delay periods available, and choice of exact time of detona
tion. Noise and potential public relations problems are reduced by
initiating the charge in the borehole with a blasting cap instead of using
trunk lines and down lines of detonating fuse. Care should be used to
avoid stray, induced electric currents or those caused by lightning or
radio frequency energy (see para 1-3). Manufacturer’s data should be
consulted for current requirements. Because of variation from brand
to brand, mixing brands of caps in a round should not be done.
(3) A delay element of explosive is placed between the bridge
wire and the primer charge in a delay electric cap. The delay element
is accurately calibrated to give a specified time lapse between the appli
cation of electric current and the detonation. Two series of delays are
available: short or millisecond delays, with delay increments of 25
msec in the lower range and 50 msec in the upper range; and longer de
lays, often called slow delays, with delay increments of 0.5 and 1 sec.
Where maximum fragmentation is desired, millisecond delays are used
to produce good breakage and reduce airblast and ground vibrations.
Slow delays are primarily used underground where they provide time
for rock movement between delays. Longer delays are likely to result
in coarser fragmentation than that obtained with millisecond delays.
(4) The cap and fuse is another system of initiating explosives.
A fuse cap is a small tube, closed at one end, which contains a heat
sensitive primer charge plus a base charge such as PETN. The cap
has an open space above the primer charge into which the safety fuse
is inserted (Fig. 3-7). The safety fuse consists of a core of potassium
nitrate black powder enclosed in a covering of textile and waterproof
ing compound. The several types of fuses vary in water resistance and
flexibility. Most burn at 40 seconds per foot (spf), but some burn at
30 spf. The safety fuse is butted to the charge in the cap and crimped
to form a tight bond. Cap and fuse systems, used primarily underground
where rotational firing is necessary, can give an unlimited number of
slow delay intervals. The caps are more dangerous to handle than
electric caps because the highly sensitive explosive charge is exposed.
Mishandling of the fuse can cause a change in the burning rate. High
degree of confinement increases the burning rate; high altitude
decreases the burning rate. Rates should always be determined at the
site.
b. Detonating Fuse.
(1) A detonating fuse, also called detonating cord, consists of a
core of high explosive, usually PETN, within a waterproof plastic sheath
enclosed in a reinforcing cover. Reinforcing covers come in a variety
3-22
CITY_21MC100_0 12669655
NYC-WTC_000435885
OCR can misread numbers and units. Confirm readings against the page image before using them.