EM 1110-2-3800
1 Mar 72
BASE CHARGE ^PRIMER CHARGE .SPACE FOR SAFETY FUSE
r
---- METAL SMELL
0. CAP (SECTION)
SAFETY FUSE
■
CAP ^NO GAP
hgwaMtw^igy»g<»ai8«iiaiaw^!^^
==ss
CBIMPS^
‘BLACK POWDER CORE
b. FUSE PROPERLY INSERTED IN CAP (SECTION)
(Courtesy of E. I. du Pont de Nemours & Co.J
Fig. 3-7. Safety fuse and cap
(modified from Du Pont^)
of types and tensile strengths suitable for different blasting conditions.
Detonating fuses with core loadings ranging from 1 to 400 grains per
foot (gr/ft) of PETN are available with 25- and 50-gr/ft loads most
commonly used. All grades can be detonated with a blasting cap and
have a detonation velocity of approximately 21,000 fps.
(2) The marked insensitivity to external shock and friction makes
a detonating fuse ideal for both down lines and trunk lines for primary
blasting. Since the blasting cap need not be connected into the circuit
until just prior to the time of firing, most of the hazard of premature
detonation is eliminated. Detonating fuses with loads of 25 or 50 gr/ft
will detonate any cap-sensitive explosive and are very useful when
blasting with deck charges (para 5-2c) or when using multiple boosters
with blasting agents. A detonating fuse with a core loading of 50 gr/ft
will not detonate a blasting agent.
(3) Detonating fuses have wide application in underwater work,
but the ends of the detonating fuse should be protected from water.
PETN will slowly absorb water and as a result become insensitive to
initiation. Even when damp, however, a detonating fuse will detonate
if initiated on a dry end.
(4) Millisecond delay connectors are available for use with deto
nating fuses. Each connector consists of a delay element with a length
of detonating fuse connected to each end. The connectors are tied
3-23