NYC 9/11 Public Portal Document
EM 1110-2-3800
1 Mar 72
as short as 8 msec are as effective in reducing the vibration levels
as are the longer delay intervals. There may be occasions when
5-msec delay intervals are too short for effectively reducing vibra
tion levels.
(3) For delayed blasting the maximum charge per delay inter
val can be reduced by reducing the number of holes that detonate per
delay interval. For delayed blasting where the number of holes per
delay interval is one, the maximum charge size per delay interval
can be reduced by decreasing the charge per hole. To reduce the
charge per hole requires changing the hole depth, hole size, burden,
spacing, and stemming.
(4) In some special cases it may be necessary to reduce the
charge size per delay interval by using decked charges in a single
hole separated by sufficient stemming to prevent sympathetic deto
nation. Each deck charge is then detonated at a different delay
interval.
(5) A presplit failure plane between the blast area and a
structure may or may not be effective in reducing vibration levels
at the structure. This method of reducing vibration levels at a given
location is not recommended without controlled tests with instru
mentation. For a presplit fracture plane to effectively reduce vibra
tion levels, it must intercept the travel path for the ground vibration
and be a good reflector. To be a good reflector the presplit fracture
plane must form a complete crack which is air filled. If the crack
becornes filled with water or sand or if numerous contacts exist
across the fracture plane, effective vibration reduction will not
result.
e. Calibration of Site Vibration Levels. For effective ground
vibration control, the propagation law constants H and P should be
determined for each blasting site. These constants can be determined
by measuring the three components of particle velocity at two or three
distances for several blasts of different charge sizes. The charge
size should be varied by changing the number of holes per delay in
terval. From these data, log-log plots of peak particle velocity for
each component as a function of scaled distance are made as shown
in Fig. 7-5. The data should group about a straight line. The slope
of the line is p and the value of v at D/W*/^ = 1 is H. The values
of H and p will, in general, be different for each component of peak
particle velocity (radial, vertical, and transverse). After determining
the values of H and P for one specific direction, additional data in
other directions should be obtained to determine if the propagation law
is the same for all directions from the blasting area.
7-16
CITY_21MC100_0 12669729
NYC-WTC_000435959
OCR can misread numbers and units. Confirm readings against the page image before using them.