Army blasting manual excerpt, 1972

Machine-extracted title · confidence 22%

Publishers’ manual excerpt on blasting for surface excavations.

NYC-WTC_000435845–000435989
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EM 1110-2-3800 1 Mar 72

as short as 8 msec are as effective in reducing the vibration levels as are the longer delay intervals. There may be occasions when 5-msec delay intervals are too short for effectively reducing vibra­ tion levels.

(3) For delayed blasting the maximum charge per delay inter­ val can be reduced by reducing the number of holes that detonate per delay interval. For delayed blasting where the number of holes per delay interval is one, the maximum charge size per delay interval can be reduced by decreasing the charge per hole. To reduce the charge per hole requires changing the hole depth, hole size, burden, spacing, and stemming.

(4) In some special cases it may be necessary to reduce the charge size per delay interval by using decked charges in a single hole separated by sufficient stemming to prevent sympathetic deto­ nation. Each deck charge is then detonated at a different delay interval.

(5) A presplit failure plane between the blast area and a structure may or may not be effective in reducing vibration levels at the structure. This method of reducing vibration levels at a given location is not recommended without controlled tests with instru­ mentation. For a presplit fracture plane to effectively reduce vibra­ tion levels, it must intercept the travel path for the ground vibration and be a good reflector. To be a good reflector the presplit fracture plane must form a complete crack which is air filled. If the crack becornes filled with water or sand or if numerous contacts exist across the fracture plane, effective vibration reduction will not result.

e. Calibration of Site Vibration Levels. For effective ground vibration control, the propagation law constants H and P should be determined for each blasting site. These constants can be determined by measuring the three components of particle velocity at two or three distances for several blasts of different charge sizes. The charge size should be varied by changing the number of holes per delay in­ terval. From these data, log-log plots of peak particle velocity for each component as a function of scaled distance are made as shown in Fig. 7-5. The data should group about a straight line. The slope of the line is p and the value of v at D/W*/^ = 1 is H. The values of H and p will, in general, be different for each component of peak particle velocity (radial, vertical, and transverse). After determining the values of H and P for one specific direction, additional data in other directions should be obtained to determine if the propagation law is the same for all directions from the blasting area.

7-16

CITY_21MC100_0 12669729

NYC-WTC_000435959

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435959Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →