NYC 9/11 Public Portal Document
EM 1110-2-3800
1 Mar 72
scaled distance of "20 ft/lb is relatively small. Thus, for this par
ticular site a safe scaled distance for prevention of damage to residen
tial structures by blasting -vibrations is 20 ft/lb^/^. This scaled
distance can serve as a guide at this particular site for determining the
-weight of explosive per delay interval that can be used at a given dis
tance from a residential structure without exceeding the safe vibration
level. All that is necessary is to make the charge weight per delay
interval sufficiently small or the distance sufficiently large so that the
quantity D/W^/^ is greater than 20 ft/lb^/^.
(5) The above-described procedure for obtaining a safe scaled
distance for prevention of damage to structures by means of ground
■vibrations from blasting implies that at a particular site, a series of
blasting tests must be conducted to determine the particle-velocity
propagation relation for that site. Such a procedure may not be neces
sary if one is -villing to accept rather large scaled distances and if one
has available particle-velocity propagation data from a large number of
sites.
(6) A scaled distance of 50 ft/lb can be considered a mini
mum safe scaled distance for any blasting site without prior knowledge
concerning its vibration characteristics. If at any site a scaled dis
tance of 50 ft/lb^/^ limits the charge weight per delay inter-val un
reasonably because of the close proximity of residential structures, it
may be possible to use a smaller scaled distance by performing tests
at the site to determine the constants in the propagation equation.
d. Reducing Vibrations.
(1) As explained above, the general propagation relation for
ground -vibrations from blasting is of the form
1/2 -P
V = H(D/w’/^)
The quantity (D/W ) is the scaled distance. The particle velocity
varies inversely -with scaled distance, and ground -vibration levels can
be reduced by increasing the scaled distance. To increase the scaled
dis-tance requires increasing the distance or decreasing the charge size
per delay interval.
(2) For instantaneous blasting, the charge size can be reduced by-
using standard or millisecond-delay detonators. For delayed detona
tions the effective charge size that controls the level of vibration is the
maximum amount of charge detonated per delay interval. The total num
ber of delays used does not affect the vibration level. Delay intervals
7-15
CITY_21MC100_012669728
NYC-WTC_000435958
OCR can misread numbers and units. Confirm readings against the page image before using them.