• Routine maintenance of pump will be performed according to the manufacturer’s instructions
on the following schedule:
_______ Part Replacement Interval (hours)
Valves 2,000
Pump Diaphragm 2,500
Dampner 2,500
Motor 4,500
Note: Replacement intervals may be shorter in dusty conditions.
Flow Rate Verification - On a weekly basis, the field technician will verify the sampling
flow rate on the sampling pump using a rotometer, bubble meter, or other suitable flow
measuring device that is NIST traceable. The flow rate should not vary from the set point by
more than +10%. If it does, the flow through the pump must be recalibrated.
PCDDs/PCDFs and PAHs Using a PS-1 High Volume Sampler
Table 13-Ic summarizes the maintenance, testing, and inspection activities for the PS-1
samplers.
Table 13-lc. Maintenance, Testing, and Inspection Requirements for the PS-
1 Sampler Used for PCDDs/PCDFs and PAHs
Acceptance
Equipment Frequency/Method Corrective Action
Criteria
PS-1 sampler Single point flow check Within + 20% of the Service PS-lsampler
at normal operating flow flow rate indicated by and perform a new
rate on weekly basis the PS-1 sampler multi-point
calibration.
Power cords Check for crimps or No obvious damage Replace as necessary
cracks
Cartridge Assembly Visually check on No obvious deposits Wipe clean daily
sample recovery days
Gaskets At 3 month intervals, No leaks or Replace as necessary
inspect all gaskets in the compression damage
sampler evident
Brushes Replace after 600 - Stable flow rate Replace as necessary
1000 hrs. of operation
Motor Replace as needed Consult manufacturer Obtain the correct
for correct model of model
motor
Tubing and fittings Visually inspect on No crimps, cracks, or Replace as necessary
sample recovery days obstructions; no
crossthreading