Ambient Air Monitoring Program Section No. 13 Quality Assurance Project Plan Revision No.: 0 130 1 .iberty Street - NY, NY Date: August 2005 Lower Manhattan Development Corporation Page 83 of 116

• Routine maintenance of pump will be performed according to the manufacturer’s instructions on the following schedule:

_______ Part Replacement Interval (hours) Valves 2,000 Pump Diaphragm 2,500 Dampner 2,500 Motor 4,500

Note: Replacement intervals may be shorter in dusty conditions.

• Flow Rate Verification - On a weekly basis, the field technician will verify the sampling flow rate on the sampling pump using a rotometer, bubble meter, or other suitable flow­ measuring device that is NIST traceable. The flow rate should not vary from the set point by more than ±10%. If it does, the flow through the pump must be recalibrated.

PCDDs/PCDFs and PAHs Using a PS-1 High Volume Sampler

Table 13-Ic summarizes the maintenance, testing, and inspection activities for the PS-1 samplers.

Table 13-lc. Maintenance, Testing, and Inspection Requirements for the PS- 1 Sampler Used for PCDDs/PCDFs and PAHs Acceptance Equipment Frequency/Method Corrective Action Criteria PS-1 sampler Single point flow check Within + 20% of the Service PS-lsampler at normal operating flow flow rate indicated by and perform a new rate on weekly basis the PS-1 sampler multi-point calibration. Power cords Check for crimps or No obvious damage Replace as necessary cracks Cartridge Assembly Visually check on No obvious deposits Wipe clean daily sample recovery days Gaskets At 3 month intervals, No leaks or Replace as necessary inspect all gaskets in the compression damage sampler evident Brushes Replace after 600 - Stable flow rate Replace as necessary 1000 hrs. of operation Motor Replace as needed Consult manufacturer Obtain the correct for correct model of model motor Tubing and fittings Visually inspect on No crimps, cracks, or Replace as necessary sample recovery days obstructions; no crossthreading

L2005-346 Rev. 1

CITY_21MC100_003239376

NYC-WTC_000449731

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449731Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000428324

Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).

Similar indexed content

NYC-WTC_000441561

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

Similar indexed content

NYC-WTC_000427221

Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

Compare copies and versions →