11.0 ANALYTICAL REQUIREMENTS
11.1 Analytical Methods
This section of the QAPP describes the analytical techniques that will be used by the fixed
laboratories to generate definitive data for the project. It documents the fixed laboratory
analytical methods that will be used to meet measurement perfoimance criteria and achieve the
project-required quantitation limits for all contaminants of concern in the specific matrices as
identified on Table 8-1.
11.1.1 Fixed Laboratory Analytical Methods and SOPs
Table 11-1 details the analytical methods that will be used in this investigation
11.1.2 Fixed Laboratory Analytical Method/SOP Modifications
The cited methods will be followed as written with the exceptions summarized below. These
modifications do not adversely affect the quality or usability of the data as sufficient quality
control analyses will be performed demonstrating adequate method performance with these
modifications.
11.1.2.1 PAH Extraction by EPA Method TO-13A and Analysis by SW-846 Method
8270C
The analysis of PAHs using SW-846 Method 8270C will be modified to include the use of
selective ion monitoring (SIM). Modifications to the sample preparation procedure in EPA
Method TO-13 are listed below.
• The XAD-2 resin is dried in a fume hood for 16 hours instead of dried in a vacuum oven with
ultra-pure nitrogen for 2-4 hours.
• The laboratory uses methylene chloride-rinsed aluminum foil instead of hexane-rinsed
aluminum foil.
• The laboratory uses methylene chloride for the extraction solvent instead of 10%
ether/hexane and therefore does not perform the precleaning extraction of 800 mL methylene
chloride of the Soxhlet apparatus.
• The final extract is brought down to a volume of 0.5 mL in methylene chloride.
11.1.2.2 Dioxin Extraction by EPA Method TO-9A
• The laboratory uses toluene for the extraction solvent instead of 10% diethyl ether/hexane.