Ambient air monitoring program plan, Liberty Street project, Sep 2005

Machine-extracted title · confidence 42%

Quality assurance plan for ambient air monitoring at the Liberty Street deconstruction site, Sep 2005.

NYC-WTC_000451508–000451641
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 11 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 1, 2005 Lower Manhattan Development Corporation Page 75 of 124

11.0 ANALYTICAL REQUIREMENTS

11.1 Analytical Methods

This section of the QAPP describes the analytical techniques that will be used by the fixed laboratories to generate definitive data for the project. It documents the fixed laboratory analytical methods that will be used to meet measurement performance criteria and achieve the project-required quantitation limits for all contaminants of concern in the specific matrices as identified on Table 8-1.

11.1.1 Fixed Laboratory Analytical Methods and SOPs

Table 11-1 details the analytical methods that will be used in this investigation

11.1.2 Fixed Laboratory Analytical Method/SOP Modifications

The cited methods will be followed as written with the exceptions summarized below. These modifications do not adversely affect the quality or usability of the data as sufficient quality control analyses will be performed demonstrating adequate method performance with these modifications.

11.1.2.1 PAH Extraction by EPA Method T0-13A and Analysis by SW-846 Method 8270C

The analysis of PAHs using SW-846 Method 827OC will be modified to include the use of selective ion monitoring (SIM). Modifications to the sample preparation procedure in EPA Method TO-13 are listed below.

• The XAD-2 resin is dried in a fume hood for 16 hours instead of dried in a vacuum oven with ultra-pure nitrogen for 2-4 hours. • The laboratory uses methylene chloride-rinsed aluminum foil instead of hexane-rinsed aluminum foil. • The laboratory uses methylene chloride for the extraction solvent instead of 10% ether/hexane and therefore does not perform the precleaning extraction of 800 mL methylene chloride of the Soxhlet apparatus. • The final extract is brought down to a volume of 0.5 mL in methylene chloride.

11.1.2.2 Dioxin Extraction by EPA Method T0-9A

• The laboratory uses toluene for the extraction solvent instead of 10% diethyl ether/hexane.

L2005-346 Rev. 1

CITY_21MC100_0 02651998

NYC-WTC_000451583

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451583Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000440540

QA Plan document for ambient air monitoring at the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000421577

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

Compare copies and versions →