Quality Assurance Plan for Ambient Air Monitoring, 130 Liberty Street

Machine-extracted title · confidence 60%

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

NYC-WTC_000421972–000422103
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 11 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 74 of 124

11.0 ANALYTICAL REQUIREMENTS

11.1 Analytical Methods

This section of the QAPP describes the analytical techniques that will be used by the fixed laboratories to generate definitive data for the project. It documents the fixed laboratory analytical methods that will be used to meet measurement performance criteria and achieve the project-required quantitation limits for all contaminants of concern in the specific matrices as identified on Table 8-1.

11.1.1 Fixed Laboratory Analytical Methods and SOPs

Table 11-1 details the analytical methods that will be used in this investigation

11.1.2 Fixed Laboratory Analytical Method/SOP Modifications

The cited methods will be followed as written with the exceptions summarized below. These modifications do not adversely affect the quality or usability of the data as sufficient quality control analyses will be performed demonstrating adequate method performance with these modifications.

11.1.2.1 PAH Extraction by EPA Method T0-13A and Analysis by SW-846 Method 8270C

The analysis of PAHs using SW-846 Method 8270C will be modified to include the use of selective ion monitoring (SIM). Modifications to the sample preparation procedure in EPA Method TO-13 are listed below.

• The XAD-2 resin is dried in a fume hood for 16 hours instead of dried in a vacuum oven with ultra-pure nitrogen for 2-4 hours. • The laboratory uses methylene chloride-rinsed aluminum foil instead of hexane-rinsed aluminum foil. • The laboratory uses methylene chloride for the extraction solvent instead of 10% ether/hexane and therefore does not perform the precleaning extraction of 800 mL methylene chloride of the Soxhlet apparatus. • The final extract is brought down to a volume of 0.5 mL in methylene chloride.

11.1.2.2 Dioxin Extraction by EPA Method T0-9A

• The laboratory uses toluene for the extraction solvent instead of 10% diethyl ether/hexane.

CITY_DEP_WORBY_CANNATA_SUBP_000052441

NYC-WTC_000422046

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422046Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →