Quality Assurance Plan for Ambient Air Monitoring, 130 Liberty Street

Machine-extracted title · confidence 60%

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

NYC-WTC_000421972–000422103
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 11 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 75 of 124

Table 11-1. Summary of Preparation and Analytical Methods Preparation Methods Analytical Method Metals 40 CFR Part 50 Appendix G - Reference S'W-846 Method 6020A Method for the Determination of Lead in Suspended Particulate Matter Collected from Ambient Air___________________________ Total Mercury EPA Method 324, Determination of Vapor EPA Method 324, Determination of Vapor Phase Flue Gas Mercury Emissions from Phase Eluc Gas Mercury Emissions from Stationaiy Sources using Dry Sorbent Trap Stationaiy Sources using Dry Sorbent Trap Sampling Sampling Asbestos NA TEM: 40 CER Part 763, Asbestos Hazard Emergency Response Act (AHERA), 1987 SEM: German VDI Method 3492________ Silica NA NIOSH Method 7500, Crystalline Silica by XRD (filter redeposition). Issue 4, March 2003________________________________ Particulate PMio NA______________________________ 40 CFR Part 50, Appendix J_____________ Particulate PM2.5 NA 40 CFR Part 50, Appendix L PCDDs/PCDEs LPA Method 1'0-9 A_______________ EPA Method 1'0-9A___________________ PCBs EPA Method TO-lOA/S'W-846 3665A, S'W-846 Method 8082 36606____________________________ PAHs EPA Method TO-13A______________ SW-846 Method 8270C_________ Gaseous Mercury NA Ohio Lumex RA 915 + duect read

TO-9A: Determination of Polychlorinated, Polybrominated and Brominated/Chlorinated Dibenzo-p-Dioxin and Dibenzofurans in Ambient Air, January' 1999. TO-lOA Determination of Pesticides and Polychlorinated Biphenyls in Ambient Air Using Low Volume Polyurethane Foam (PUF) Sampling Followed by Gas Chromatographic/Multi-Dctcctor Detection (GC/MD), January 1999. TO-13A: Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Ambient Air Using Gas Chromatographic/Mass Spectrometry (GC/MS), January 1999.

/1.1.2.3 Asbestos Analyses by TEM (AHERA)

Asbestos analysis will be performed utilizing Transmission Electron Microscopy (TEM) analysis specified in 40 CFR Part 763, Asbestos Hazard Emergency Response Act, (AHERA) in order to measure structures/mm^, with the following modifications:

• The sensitivity on TEM air samples will be less than 0.002 structures/cc. The laboratory will analyze up to 10 grid openings on the TEM in order to achieve this sensitivity. • Both length and width of all asbestos fibers will be recorded. • Confirmation by Energy Dispersive Spectroscopy (EDS) and/or Selected Area Electron Diffraction (SAED) will be performed for each sample. • The morphology of the fibers will be noted by the aspect ratio and recorded.

In addition to the standard AHERA analysis provided for each sample, a second analysis will be performed for asbestos PCM equivalent (PCME) fibers. These fibers will be defined as any asbestos fiber or bundle with the following features:

CITY_DEP_WORBY_CANNATA_SUBP_000052442

NYC-WTC_000422047

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422047Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →