NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Ambient air monitoring program plan, Liberty Street project, Sep 2005

Machine-extracted title · confidence 42%

Quality assurance plan for ambient air monitoring at the Liberty Street deconstruction site, Sep 2005.

NYC-WTC_000451508–000451641
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 1, 2005 Lower Manhattan Development Corporation Page 74 of 124

Total Mercury

In addition, during the background phase of the program, the accuracy and precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy and precision of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

10.3.5 Breakthrough Checks

Separate analyses of both front and back half portions of carbon traps for mercury will be performed during the background phase to allow for an assessment of analyte breakthrough. The breakthrough assessment will be performed on all stations during the background phase. Breakthrough on the back half of the trap must be < 2% of the front half of the trap or < 5 ng per trap. If breakthrough criteria are consistently met during the background phase, subsequent measurement will be performed with the front and back halves of the carbon traps combined for analyses.

10.3.6 Media Certification Checks

Media for all analyses collected a on time-integrated basis will be certified clean from the laboratories. The certifications will be performed as batch checks and results will be stored in the project files.

L2005-346 Rev. 1

CITY_21MC100_0 02651997

NYC-WTC_000451582

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451582Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000440540

QA Plan document for ambient air monitoring at the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000421577

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

Compare copies and versions →