NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 11
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 68 of 116
Table 11-1. Summary of Preparation and Analytical Methods
Preparation Methods Analytical Method
Metals 40 CFR Part 50 Appendix G - Reference SW-846 Method 6020A
Method for the Determination of Lead in
Suspended Particulate Matter Collected from
Ambient Air___________________________
Total Mercury EPA Method 324, Determination of Vapor EPA Method 324, Determination of Vapor
Phase Flue Gas Mercury Emissions from Phase Flue Gas Mercury Emissions from
Stationary Sources using Dry Sorbent Trap Stationary Sources using Dry Sorbent Trap
Sampling Sampling
Asbestos NA TEM: 40 CFR Part 763, Asbestos Hazard
Emergency Response Act (AHERA), 1987
SEM: German VDI Method 3492________
Silica NA NIOSH Method 7500, Crystalline Silica by
XRD (filter redeposition). Issue 4, March
2003__________________________
Particulate PM^ NA______________________________ 40 CFR Part 50, Appendix J_____________
Particulate PM2.5 NA 40 CFR Part 50, Appendix L____________
PCDDs/PCDFs EPA Method TO-9A_______________ EPA Method TO-9A___________________
PCBs EPA Method TO-1OA/SW-846 3665A, SW-846 Method 8082
3660B____________________________
PAHs__________ EPA Method TO-13A______________ SW-846 Method 8270C_________
Gaseous Mercury NA Ohio Lumex RA 915 + direct read
TO-9A: DeLerminaLion of Polychlorinated, Polybrominated and Brominated/Chlorinated Dibenzo-p-Dioxin and Dibenzoftirans in Ambient
Air, January 1999.
TO-lOA Determination of Pesticides and Polychlorinated Biphenyls in Ambient Air Using Low Volume Polyurethane Foam (PUF) Sampling
Followed by Gas Chromatographic/Multi-Detector Detection (GC/MD), January 1999.
TO-13A: Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Ambient Air Using Gas Chromatographic/Mass Spectrometry
(GC/MS), January 1999.
10-3.5: Determination of Metals in Ambient Particulate Matter Using Inductively Coupled Plasma/Mass Spectrometry (ICP/MS), June 1999.
1].1.2.3 Asbestos Analyses by TEM (AHERA)
Asbestos analysis will be performed utilizing Transmission Electron Microscopy (TEM) analysis
specified in 40 CFR Part 763, Asbestos Hazard Emergency Response Act, (AHERA), with the
following modifications:
• The sensitivity on TEM air samples will be less than 0.002 s/cc. The laboratory will analyze
up to 10 grid openings on the TEM in order to achieve this sensitivity.
• Both length and width of all asbestos fibers will be recorded.
• Confirmation by Energy Dispersive Spectroscopy (EDS) and/or Selected Area Electron
Diffraction (SAED) will be performed for each sample.
• The morphology of the fibers will be noted by the aspect ratio and recorded.
In addition, samples may also be analyzed using Scanning Electron Microscopy (SEM) due to
the potential overloading problem with TEM which may be caused by excess particulates. This
L2005-346 Rev. 1
C ITY_D E P_W0 RB Y_C AN N ATA_SU B P_000114709
NYC-WTC_000428392
OCR can misread numbers and units. Confirm readings against the page image before using them.