NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 11
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 69 of 116
will be determined on a sample-specific basis and performed as needed. SEM is a well-
established methodology that utilizes a scanning electron microscope. The SEM can work in
many different magnification ranges from lOOx to 20,000x. The sample preparation is different
than TEM, whereas samples ;irc gold coated and mounted on a stub, with minimal degradation to
the original sample. The SEM is more flexible with regard to types of material you can
introduce into the chamber. SEM can achieve much better contrast than TEM and results in
almost a 3-D image whereas the TEM is a 2-D “shadow”. SEMs are typically equipped with
Energy Dispersive X-Ray analyzers (EDXA) just like TEM. This enables the analyst to
determine the elemental composition of a material or fiber observed. The SEM is not equipped
with Electron Diffraction capabilities unlike the TEM, which allows the analyst to determine the
crystal structure of a mineral based on a distinct pattern of spots that is produced from the
bombardment of an electron beam. Selected Area Electron Diffraction (SAED) is cited in many
TEM methods including AHERA and is required to yield a definitive asbestos identification.
For this project, however, since the dust has been so well characterized, the need for SAED is not
as essential.
11.1.2.4 Metals Analysis by SW-846 Method 602OA
Metals analysis will be performed using SW-846 Method 6020A with the following
modifications;
• Samples will be digested using nitric acid as per 40 CFR Part 50 Appendix J, not a mixture
of nitric and hydrochloric acid. Sample digestion will be performed using a hotplate or Mod-
block digestion procedure.
• Initial ICP/MS instrument calibration will be performed using a blank and a single-point
standard.
• The routine calibration procedure will not include the analysis of a High Standard
Verification (HSV) standard. Calibration will be verified with the CCB and CCV.
• The laboratory will perform the metals analysis by scanning the selected ion, not scanning all
ions from 5-250 amu.
• The internal standard mixture used by the laboratory will include Li, Ge, In, Tm, and Bi.
11.2 Analytical Quality Control
Tables 8-2 through 8-9 summarize the QC procedures checks, and samples, and their respective
acceptance limits for each fixed laboratory analytical parameter that will be used during the
project.
11.2.1 Field Analytical QC
Calibration procedures discussed in Section 13.2.1 will be adhered to for field analyses of
gaseous mercury in order to ensure the accuracy of sample measurements.
L2005-346 Rev. 1
CITY_DEP_WORBY_CANNATA_SUBP_000114710
NYC-WTC_000428393
OCR can misread numbers and units. Confirm readings against the page image before using them.