analytical reproducibility. With the exception of mercury, field duplicates will be submitted at a
frequency of once per week per analytical parameter. For mercury, field duplicates and field
spikes will be alternated on a weekly basis.
10.3.4 Field Spikes
PCDDs and PAHs
Field spikes are clean media used for sampling and pre-spiked with ^^Cn-labeled compounds
(similar to the target analytes) and used to evaluate overall accuracy. The media will be spiked
in the laboratory, sent out to the field with all sample media, and returned to the laboratory for
analysis.
Mercury
In addition, during the background phase of the program, the accuracy and precision of the
mercury sampling and analysis method will be tested. Ambient air samples will be collected at
one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These
samples will provide data on the accuracy and precision of the method under actual field
sampling condition. Following the background phase, one field spike will be performed every
other week.
10.3.5 Breakthrough Checks
Separate analyses of both front and back half portions of carbon traps for mercury will be
performed during the background phase to allow for an assessment of analyte breakthrough. The
breakthrough assessment will be performed on all stations during the background phase.
Breakthrough on the back half of the trap must be < 2% of the front half of the trap or < 5 ng per
trap. If breakthrough criteria are consistently met during the background phase, subsequent
measurement will be performed with the front and back halves of the carbon traps combined for
analyses.
10.3.6 Media Certification Checks
Media for all analyses collected a on time-integrated basis will be certified clean from the
laboratories. The certifications will be performed as batch checks and results will be stored in
the project files.