10.2.10.2 Continuous Monitoring of PM2.5 via Met One E-BAM Samplers
The monitors selected to continuously measure PM2.5 are beta-attenuation monitors manufactured
by Met One Instruments, Inc. (Met One).
The E-BAM monitors will be equipped with particle size selective inlets. The design of the
inlets is such that particles larger than the desired size range will be removed from the air flow at
the prescribed air flow rate. The units will be equipped with an inlet head to separate PM2.5.
Sampling flow rate is critical to maintain the proper particle size cut points of the inlets. Flow
rates are maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow
meter, pressure sensor, and ambient temperature sensor on board each monitor.
10.3 Field Quality Control
This section of the QAPP identifies the QC procedures, checks, samples, and their respective
acceptance limits, that will be used to monitor the quality of various aspects of the sampling
event. Their required analysis frequency, acceptance limits and corrective actions are also
documented in this section of the QAPP.
10.3.1 Field Blanks/Trip Blanks
Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to the site
and return to the laboratory in the same cooler or shipping container. Field/trip blanks will be
used to ensure that there is no contamination as a result of the shipment/transportation/on-site
storage activities. Field/trip blanks will be collected for all parameters associated with ah’
samples. Field/trip blanks for asbestos and silica will only be analyzed if the asbestos or silica
are detected in the associated samples.
10.3.2 Cooler Temperature Blanks
Cooler temperature blanks consist of a sample container filled with non-preserved water (potable
or distilled) and are included in all coolers which contain samples which require temperature
preservation (PAHs, PCBs, PCDDs/PCDFs). The laboratory uses these temperature blanks to
ensure that proper preservation of the samples has been maintained during sample shipment.
The temperature of these blanks must be 4 °C +2° to demonstrate that proper preservation has
been maintained. The laboratory records the results of the temperature blanks on the chain-of-
custody or sample login form immediately upon receipt of the samples at the laboratory, prior to
inventory and refrigeration.
10.3.3 Field Duplicates
Field duplicates will be collocated samples. Collocated samples are two samples collected next
to each other in the same vertical position. Collocated samples require two separate sample
collections at the same location. Field duplicates will be used to assess the sampling and