NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 10
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 61 of 116
• Quartz Fiber Filter - 102 mm binderless quartz microfiber filter. (Provided by the
laboratory, pre-cleaned and weighed.)
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022
g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the
cartridge.
XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges. Supelco (or
equivalent). Pre-cleaned and assembled by the analytical laboratory.
• White Cotton Gloves - For handling the filters and cartridges.
• Sample Cartridge Shipping Containers - The analytical laboratory will provide individually
labeled containers that will be used to transport the sample cartridges to the field location and
back to the laboratory for analysis. This will include aluminum foil wrapped around the
cartridge and a glass jar large enough to hold the cartridge.
• 0-100” Magnehelic Gage.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
10.2.8 Mercury (Total)
An iodated carbon trap is used to collect total mercury (particulate associated and vapor). The
samples are then analyzed using cold vapor atomic fluorescence (CVAFS). The carbon trap is a
proven and sensitive method for detecting trace ambient levels of atmospheric mercury. To
collect the mercury sample, a personal sampling pump will be attached to the carbon trap and set
at a flow rate of approximately 0.4 liters per minute for 24 hours for a resulting total air volume
of approximately 0.6 nt . There will be either be an arrow on the tube indicating the direction of
the air flow or the technician should be aware that air needs to flow into the section of the tube
with the larger portion of sorbent. Prior to collection, the end plugs of the carbon traps will be
removed while wearing clean gloves and placed into the bag in which the tube was received. At
the completion of sampling, these plugs will be placed back on the carbon traps while wearing
clean gloves. It is essential that these plugs be kept clean during the sampling process.
Equipment and supplies utilized with this sampling approach are as follows:
• Personal Sampling Pump - The pump used to draw the air through the iodated carbon trap.
Flow Measurement Device - A device such as a rotameter, bubble meter, or gas volume
displacement-measuring device such as a “DryCal” flow meter. This device should have a
calibration traceable to a NIST certification.
L2005-346 Rev. 1
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114702
NYC-WTC_000428385
OCR can misread numbers and units. Confirm readings against the page image before using them.