NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Quality Assurance Plan, Ambient Air Monitoring, LMDC

Machine-extracted title · confidence 39%

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

NYC-WTC_000447031–000447162
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 68 of 124

• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the cartridge.

XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges. Supelco (or equivalent). Pre-cleaned and assembled by the analytical laboratory.

• White Cotton Gloves - For handling the filters and cartridges.

• Sample Cartridge Shipping Containers - The analytical laboratory will provide individually labeled containers that will be used to transport the sample cartridges to the field location and back to the laboratory for analysis. This will include aluminum foil wrapped around the cartridge and a glass jar large enough to hold the cartridge.

• 0-100” Magnehelic Gage.

• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.

10.2.8 Mercury (Total)

An iodated carbon trap is used to collect total mercury (particulate associated and vapor). The samples are then analyzed using cold vapor atomic fluorescence (CVAFS). The carbon trap is a proven and sensitive method for detecting trace ambient levels of atmospheric mercury. To collect the mercury sample, a personal sampling pump will be attached to the carbon trap and set at a flow rate of approximately 0.4 liters per minute for 24 hours for a resulting total air volume of approximately 0.6 m^. There will be either be an arrow on the tube indicating the direction of the air flow or the technician should be aware that air needs to flow into the section of the tube with the larger portion of sorbent. Prior to collection, the end plugs of the carbon traps will be removed while wearing clean gloves and placed into the bag in which the tube was received. At the completion of sampling, these plugs will be placed back on the carbon traps while wearing clean gloves. It is essential that these plugs be kept clean during the sampling process.

Equipment and supplies utilized with this sampling approach are as follows:

• Personal Sampling Pump - The pump used to draw the air through the iodated carbon trap.

Flow Measurement Device - A device such as a rotameter, bubble meter, or gas volume displacement-measuring device such as a “DryCal” flow meter. This device should have a calibration traceable to a NIST certification.

• lodated Carbon Trap - The carbon trap provided by the subcontracted laboratory that is used to absorb the mercury from the air that is passed through it.

CITY_21MC100_003212814

NYC-WTC_000447099

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447099Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →