• lodated Carbon Trap - The carbon trap provided by the subcontracted laboratory that is used
to absorb the mercury from the air that is passed through it.
10.2.9 PMio
PMio will be determined by two separate methods. At each location, PM k, will be determined by
a non-reference method utilizing Met One’s E-BAM Mass Monitor, which is a real-time
monitor. Anderson RAAS samplers will be used to collect PMio via the US EPA standard
reference method (40 CFR Part 50 Appendix J) at one location each day. An Anderson RAAS
PMio sampler will be collocated along side the real-time PMio monitors as a QA check. The
Anderson RAAS sampler will rotate on a monthly basis through all real-time PMio monitor
locations for the duration of the monitoring program.
JO.2.9.1 PMio - Reference Method via Anderson RAAS samplers
Particulate samples whose aerodynamic diameter is < 10 p will be collected using Andersen
RAAS samplers operating in the PMio mode. All samples will be collected over an estimated
twenty-four hour sampling interval at a prescribed flow rate of 16.67 liters/minute. This equates
to a corrected air volume of 24 m^ per each twenty-four hour sampling event. Pre-weighed
Teflon filters (47mm diameter) provided by the subcontracted laboratory will be placed in the
RAAS sampler cassette prior to the start of each sampling event.
The sampler specification for the PMio sampler is contained in 40 CER Part 50 Appendix J. This
document specifies the PMio sampling limits, protocol, and instrument specifications. The
RAAS systems perform all of the functions required or recommended in the instrument
specification part of the standard. The inlet has a 10-micrometer (nominal) cutpoint. The inlet
provides wind speed and direction independent sampling and removes particles larger than about
10 micrometers.
Before sampling, the filters are equilibrated to constant temperature and relative humidity
conditions and weighed. After sampling, the filters are again equilibrated to the constant
temperature and humidity conditions and weighed. The mass concentration is then calculated by
dividing the weight of the particulate captured on the filter by the volume of air (at ambient
conditions) that passed through the sampler. The flow rate is required to be maintained within
5% of 16.67 liters per minute with a coefficient of variation (a measure of the average short-term
variation in flow in %) of less than 2%.
Equipment and supplies utilized with this sampling approach are as follows:
• Filters - Preweighed 47-mm Teflon® filters. Filters should be stored and transported in petri
dishes.
• Forceps - Non-serrated forceps should be used to handle the 47-mm filters.