NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 10
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 58 of 116
• Sample Cartridge Aluminum Shipping Containers - The analytical laboratory will provide
individually labeled containers that will be used to transport the sample cartridges to the field
location and back to the laboratory for analysis.
• 0-100” Magnehelic Gage.
• White Cotton Gloves - For handling the filters and cartridges.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
10.2.6 Polychlorinated Biphenyls (PCBs)
Ambient air samples will be collected using a low-volume SKC Leland Legacy personal
sampling pump equipped with a glass cylinder containing a polyurethane sorbent (i.e., PUF plug)
for the collection of gas and particulate phase PCBs. Samples will be collected at a flow rate of
five liters per minute (5 1pm) with a sampling period of approximately 24 hours for a resulting
total air volume of approximately 7.2 cubic meters (7.2 m^).
The PUF (Polyurethane Foam) sampler is an air sampling system designed to trap airborne
organic vapors. The PUF sampler is equipped with a low-volume pump. This feature is
designed to permit the motor to operate at low sampling flow rates for extended periods without
motor failure from overheating. The sampling cartridge is constructed of borosilicate glass, is
filled with the PUF plug, and is connected to the sampling pump by way of flexible tubing.
Pump flow rates of each personal sampling pump, with a representative sampler in line, will be
measured before and after sample collection. The pump will be run for 10 minutes prior to
checking the flow rate. A suitable rotameter (or bubble meter) will be connected to the filter
inlet, the flow screw adjusted to the desired sampling value, and the flow rate observed on the
rotameter (or bubble meter) will be verified as constant for a minimum of 20 seconds. Flow
rates will be recorded on Field Sampling Data Sheets or an equivalent field logbook.
To initiate sample collection, the aluminum foil is removed from the pre-cleaned cartridge
assembly (foil returned to the jar for later use) and the cartridge is attached to the pump with
flexible tubing. The sampling assembly is positioned with the intake downward or in a
horizontal position. The samplers are fastened to a location (i.e., on a tripod) near the
individual’s breathing zone at least 30 meters from any obstacle from air flow with the PUF
intake and at least 1 to 2 meters above ground level. After the PUF cartridge is correctly inserted
and positioned, the power switch is turned on, the elapsed time meter is activated, sampling
begins, and the start time is recorded on the Field Data Sheet or equivalent field logbook.
At the conclusion of each sampling period, the power switch is turned off, stop time recorded,
the PUF cartridge is removed from the pump and wrapped with its original aluminum foil, the
L2005-346 Rev. 1
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114699
NYC-WTC_000428382
OCR can misread numbers and units. Confirm readings against the page image before using them.