Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 1301 jberty Street - NY, NY Date: August 2005 Lower Manhattan Development Coi-poration Page 58 of 116

• Sample Cartridge Aluminum Shipping Containers - The analytical laboratory will provide individually labeled containers that will be used to transport the sample cartridges to the field location and back to the laboratory for analysis.

• 0-100” Magnehelic Gage.

• White Cotton Gloves - For handling the filters and cartridges.

• lee Chests - To hold samples at 4°C during shipment to the analytical laboratory.

10.2.6 Polychlorinated Biphenyls (PCBs)

Ambient air samples will be collected using a low-volume SKC Leland Legacy personal sampling pump equipped with a glass cylinder containing a polyurethane sorbent (i.e., PUF plug) for the collection of gas and particulate phase PCBs. Samples will be collected at a flow rate of five liters per minute (5 1pm) with a sampling period of approximately 24 hours for a resulting total air volume of approximately 7.2 cubic meters (7.2 m^).

The PUF (Polyurethane Foam) sampler is an air sampling system designed to trap airborne organic vapors. The PUF sampler is equipped with a low-volume pump. This feature is designed to permit the motor to operate at low sampling flow rates for extended periods without motor failure from overheating. The sampling cartridge is constructed of borosilicate glass, is filled with the PUF plug, and is connected to the sampling pump by way of flexible tubing.

Pump flow rates of each personal sampling pump, with a representative sampler in line, will be measured before and after sample collection. The pump will be run for 10 minutes prior to checking the flow rate. A suitable rotameter (or bubble meter) will be connected to the filter inlet, the flow screw adjusted to the desired sampling value, and the flow rate observed on the rotameter (or bubble meter) will be verified as constant for a minimum of 20 seconds. Flow rates will be recorded on Field Sampling Data Sheets or an equivalent field logbook.

To initiate sample collection, the aluminum foil is removed from the pre-cleaned cartridge assembly (foil returned to the jar for later use) and the cartridge is attached to the pump with flexible tubing. The sampling assembly is positioned with the intake downward or in a horizontal position. The samplers are fastened to a location (i.e., on a tripod) near the individual’s breathing zone at least 30 meters from any obstacle from air flow with the PUF intake and at least 1 to 2 meters above ground level. After the PUF cartridge is correctly inserted and positioned, the power switch is turned on, the elapsed time meter is activated, sampling begins, and the start time is recorded on the Field Data Sheet or equivalent field logbook.

At the conclusion of each sampling period, the power switch is turned off, stop time recorded, the PUF cartridge is removed from the pump and wrapped with its original aluminum foil, the

L2005-346 Rev. 1

CITY_21MC100_003243464

NYC-WTC_000441619

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000441619Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449648

Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

Compare copies and versions →