The PUF (Polyurethane Foam) sampler is a complete air sampling system designed to
simultaneously collect suspended airborne particulates as well as trap airborne organic vapors.
The PUF sampler is equipped with a bypass blower motor arranged with an independent cooling
fan. This feature permits the motor to operate at low sampling flow rates for extended periods
without motor failure from overheating.
A dual chambered aluminum sampling module contains both filtering systems. The upper
chamber supports the airborne particulate filter media in a circular filter holder. The lower
chamber encapsulates a glass cartridge, which contains the PUF for vapor entrapment.
The voltage variator adjustment screw alters the blower motor speed to achieve the desired flow
rate. Air flow rate is measured through the flow venturi utilizing a 0-100” Magnehelic Gage.
For each sample, the sampling start and end times and flow rates are recorded on Field Sampling
Data Sheets or an equivalent field logbook and used to calculate the amount of ambient air
sampled.
At the conclusion of each sampling period, the sample is recovered from the sampling train by
placing the filter inside the glass cartridge. The glass cartridge is then wrapped with aluminum
foil and it is placed back into its original shipping container, labeled, and transported to the
analytical laboratory for processing.
Equipment and supplies utilized with this sampling approach are as follows:
• High-Volume Sampler - General Metals Works (GMW) PS-1 (or equivalent), capable of
pulling ambient air through the filter/adsorbent cartridge sampling train at a flow rate of 200-
300 1pm to obtain a total sample volume of 288-432 m^ over a 24-hour period.
• High-Volume Sampler Calibrator - Capable of providing multipoint resistance for the high-
volume sampler.
• Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz microfiber filter, Whatman
International Ltd, QMA-4 (or equivalent), provided by the laboratory, pre-cleaned and
weighed.
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022
g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the
cartridge.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate seal to
prevent pre- or post- sampling exposure to other potential sources of the target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will insert the
PUF plug into the glass sample cartridge during pre-sampling preparation.