Ambient Air Monitoring Program Section No. 8
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 39 of 116
In addition, during the background phase of the program, the precision of the mercury sampling
and analysis method will be tested. Ambient air samples will be collected at one location using a
series of four iodated carbon traps prespiked (50 ng/trap) with mercury. These samples will
provide data on the precision of the method under actual field sampling conditions. Following
the background phase, one field spike will be performed every other week, alternating with the
field duplicates.
Laboratory Precision Objectives
Precision in the laboratory is assessed through the calculation of RPD for duplicate preparation
and analyses of laboratory control samples, or replicate injections of samples. Laboratory
precision measures both sample preparation and analysis reproducibility. Precision control limits
and frequency of precision measurements are provided in Tables 8-2 through 8-9.
8.2.2 Accuracy
Accuracy is the closeness of agreement between an observed value and an accepted reference
value. The difference between the observed value and the reference value includes components
of both systematic error (bias) and random error.
Field Accuracy Ob jectives
Accuracy in the field is assessed through the adherence to all field instrument calibration
procedures, sample handling, preservation, and holding time requirements. Accuracy will also
be evaluated through the use of field/trip blanks, field spikes, and cooler temperature blanks.
Field/trip blanks will be collected at a frequency of one per day for each analytical parameter.
Field/trip blanks will be used to assess any contamination attributable to shipment and
transportation and/or on-site storage of samples and sample media. These blanks will be selected
from the media provided for the sampling events by the off-site laboratories and as such the
blanks will represent actual field samples with the sole exception that no air will be drawn
through them. Analysis of field/trip blanks for silica and asbestos will only occur if these
analytes are detected in samples.
In addition, during the background phase of the program, the accuracy of the mercury sampling
and analysis method will be tested. Ambient air samples will be collected at one location using a
series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data
on the accuracy of the method under actual field sampling condition. Following the background
phase, one field spike will be performed every other week.