Ambient Air Monitoring Program Section No. 8
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 38 of 116
The measurement performance criteria for each parameter are further defined in this section.
The number of samples needed for each parameter and matrix were defined in the Ambient Air
Monitoring Program for the 130 Liberty Street Deconstruction Project, August 2005 and are
summarized in Tables 7-la, 7-lb, and 7-lc.
8.2 Measurement Performance Criteria
The 130 Liberty Street Ambient Air Monitoring Program is designed to produce data of the
quality necessary to achieve PQOs and meet or exceed the minimum standard requirements for
field and analytical methods. The overall QA objective is to develop and implement procedures
for field sampling, chain-of-custody, laboratory analysis, and reporting which will provide
results that are scientifically valid, and the levels of which are sufficient to meet PQOs. Specific
procedures for sampling, chain of custody, laboratory and field instruments calibration,
laboratory analysis, reporting of data, internal quality control, preventative maintenance of field
and laboratory equipment, and corrective action are described in other sections of this QAPP.
The purpose of this section is to state the specific, required QA objectives for accuracy,
precision, representativeness, completeness, sensitivity, selectivity, and comparability.
Measurement performance criteria for precision, accuracy/bias, representativeness,
completeness, sensitivity, quantitation limits, selectivity, and comparability have been
established for each parameter and are summarized in Tables 8-2 through 8-9. These measures
of performance are also referred to as Data Quality Indicators (DQIs) and are discussed in detail
below.
8.2.1 Precision
Precision is the agreement among a set of replicate measurements without consideration of the
“true” or accurate value: i.e., variability between measurements of the same material for the
same analyte. Precision is measured in a variety of ways including statistically, such as
calculating variance or standard deviation.
Field Precision Objectives
Field precision is assessed through the collection and measurement of collocated samples (also
called field duplicates) which consist of a second sample in addition to the original field sample.
In general, field duplicates will be collected at a frequency of once per week per analytical
parameter. Precision will be measured through the calculation of relative percent difference
(RPD). The resulting information will be used to assess sample homogeneity, spatial variability
at the site, sample collection reproducibility, and analytical variability. Field duplicate RPDs
must be < 40. Field precision will be maintained by utilizing experienced/trained sampling
crews and conducting field audits.