Ambient Air Monitoring Program, Draft PBP

Machine-extracted title · confidence 51%

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

NYC-WTC_000441561–000441677
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 8 Quality Assurance Project Plan Revision No.: 0 130 1 iberly Street - NY, NY Date: August 2005 Lower Manhattan Development Corporation Page 39 of 116

In addition, during the background phase of the program, the precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four iodated carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the precision of the method under actual field sampling conditions. Following the background phase, one field spike will be performed every other week, alternating with the field duplicates.

Laboratory Precision Ob jectives

Precision in the laboratory is assessed through the calculation of RPD for duplicate preparation and analyses of laboratory control samples, or replicate injections of samples. Laboratory precision measures both sample preparation and analysis reproducibility. Precision control limits and frequency of precision measurements are provided in Tables 8-2 through 8-9.

8.2.2 Accuracy

Accuracy is the closeness of agreement between an observed value and an accepted reference value. The difference between the observed value and the reference value includes components of both systematic error (bias) and random error.

Field Accuracy Objectives

Accuracy in the field is assessed through the adherence to all field instrument calibration procedures, sample handling, preservation, and holding time requirements. Accuracy will also be evaluated through the use of field/trip blanks, field spikes, and cooler temperature blanks.

Field/trip blanks will be collected at a frequency of one per day for each analytical parameter. Field/trip blanks will be used to assess any contamination attributable to shipment and transportation and/or on-site storage of samples and sample media. These blanks will be selected from the media provided for the sampling events by the off-site laboratories and as such the blanks will represent actual field samples with the sole exception that no air will be drawn through them. Analysis of field/trip blanks for silica and asbestos will only occur if these analytes are detected in samples.

In addition, during the background phase of the program, the accuracy of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

L2005-346 Rev. 1

CITY_21MC100_003243445

NYC-WTC_000441600

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000441600Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449648

Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

Compare copies and versions →