NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 7
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 32 of 116
Table 7-3. Phase II - Structural Deconstruction Phase Sampling and Analysis Summary
Location Parameter(s) Sample Frequency Analysis Method
Site Area Mercury (vapor/gas) Each Day Lumex, portable mercury
analyzer
Site Area Visible dust emissions Each Day Visual observation
Ground/Street 1. Asbestos Each Day (asbestos and 1. TEM/SEM
Level 2. Silica silica are sampled during 2. XRD
(4 Locations) work shift)
3. Metals Each Day (24 hr. Basis) 3. ICP/MS
4. PCDDs/PCDFs 4. HRGC/HRMS
5. PAHs 5. GC/MS
6. PCBs 6. GC/ECD
7. Mercury (total) 7. lodated Carbon
Trap/CVAES
8. PMio Continuously “Real-Time” 8. EB AM/Gravimetric
9. I’M; Each Day (PMw and I’M, 9. EB AM/Gravimetric
on 24 hour basis at each
location; PMio and PM2.5
reference sampler at 1
location per day on 24-
hour basis with location
changed monthly)
Roof Top and 1. Asbestos Each Day (asbestos and 1. TEM/SEM
Scaffolding 2. Silica silica are sampled during 2. XRD
(4 locations on roof work shift)
top and 4 locations 3. Metals Each Day (24 hr. Basis) 3. ICP/MS
on scaffolding) 4. PCDDs/PCDFs 4. HRGC/HRMS
5. PAIIs 5. GC/MS
6. PCBs 6. GC/ECD
7. Mercury (total) 7. lodated Carbon
Trap/eVAFS_________
8. PMio Continuously “Real-Time” 8. EB AM/Gravimetric
9. PM2.5 Each Day (PMio and PM2.5 9. EBAM/Gravimetric
on 24 hour basis at each
location; I’M],, and PM2.5
reference sampler at 1
location per day on 24-
hour basis with location
changed monthly)
Phase II - Structural Deconstruction
During Phase II of the deconstruction project, air monitoring will take place at all twelve (12)
stations each day. During the first three (3) days only of Phase II, samples will be collected at all
twelve (12) locations for semi-volatile organics to include PCDDs/PCDFs, PAHs and PCBs.
After this initial three (3) day period, samples for these organic parameters will be reduced to a
single location per week frequency employing the twelve (12) station network. More
specifically, samples will not be collected at all twelve (12) stations each day; rather a single set