NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 7
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 33 of 116
of samples will be collected each day at a single station in the network. This sequence will be
repeated each day using a different station each day until all of the twelve (12) stations have been
used. The schedule will be repeated until project completion.
The semivolatile organic samples collected employing this weekly sampling frequency will not
be processed for analyses; rather they will be placed in archival storage at the laboratory. A
single set of samples will be selected from each sample set representing seven (7) days to
undergo analyses for PCDDs/PCDFs, PAHs and PCBs. This sample set will be selected after
consideration of the PMio data corresponding to the sites and days where organic samples were
collected. The station with the highest 24-hour average PMio concentration (ug/m3) recorded
with a collocated organic sample each week will be selected for analyses.
7.1.2 Analytical Tasks
In February 2002, a multi-agency task force headed by the USEPA was formed to evaluate
indoor environments for the presence of contaminants related to the WTC terrorist attacks that
might pose long-term health risks to local residents. As part of this evaluation, a task force sub
committee was established to identify Contaminants of Potential Concern (COPC Committee)
that are likely associated with the WTC disaster and establish health-based benchmarks for those
contaminants in support of planned residential cleanup efforts in Lower Manhattan.
In addition, a number of other studies conducted by USEPA (EPA/600/R-03/142 December
2003) and work performed by Louis Berger Group were examined as a means of establishing a
listing of target parameters appropriate to satisfy the purpose and objectives of the current
deconstnxction project. These objectives include monitoring of fugitive dusts potentially related
to the deconstruction as well as identifying levels of COPCs associated with the materials at 130
Liberty Street. In this manner the deconstruction project can proceed while providing an ample
margin of safety for human health and the environment in the vicinity of the project site.
Based upon these criteria and regulatory requirements, the following target parameters were
selected for inclusion in the monitoring program:
• PMio-Respirable Particulate
• PM2.5-Respirable Particulate
• Asbestos
• Crystalline Silica
• PCDDs/PCDFs
• PAHs
• PCBs
• Metals (antimony, barium, beryllium, cadmium, chromium, copper, lead, mercury [gaseous
and total] manganese, nickel and zinc).
L2005-346 Rev. 1
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114674
NYC-WTC_000428357
OCR can misread numbers and units. Confirm readings against the page image before using them.