All data from the Background Phase will be subjected to a limited validation, which includes, at
a minimum, a completeness check, an evaluation of chain-of-custody and sample login
documents, an overall evaluation of data and potential usability issues, technical holding times,
and QC sample results (blanks, surrogate spikes, MS/MSDs, calibrations, matrix duplicates, and
LCS, etc.). Following this, a limited validation will be performed on a subset of the data. For
the first two months of the program, the validation will be performed on a weekly basis followed
by a monthly basis thereafter. Completeness checks will be adininistered on all data to
determine whether deliverables specified in the QAPP are present. The reviewer will determine
whether all required items are present and will request copies of missing deliverables.
Upon completion of the validation, a report will be prepared summarizing the elements
reviewed. Validated data will be used to generate tables.
16.2 Data Usability
The purpose of this section is to indicate the methods by which it will be ensured that the
validated laboratory data collected for this investigation are consistent with the project quality
objectives established for the project, to ensure the quality of data was sufficient for its intended
use, and to identify trends, relationships, and anomalies in the data. Conclusions based on the
data, limitations on the use of the data, and the determination if data gaps exist will be included
in the Data Validation memoranda.
16.2.1 Precision
The RPD between the LCS and LCS duplicate or sample and sample duplicate, is calculated to
compare to precision objectives. LCS/LCS duplicates and laboratory duplicates will be used to
assess analytical precision and the field duplicates will be used to assess project precision. The
RPD will be calculated according to the following formula:
_ (Amount in Sample 1 - Amount in Sample 2)
1\1 1^ — J.V\J
0.5 (Amount in Sample 1 + Amount in Sample 2)
The impact of analytical imprecision, project imprecision, and overall imprecision (when both
analytical and project precision tests show problems) on data usability will be assessed. If the
precision results yield data which are not usable, the Data Validation memoranda will identify
how this problem will be resolved and the potential need for resampling will be discussed.
16.2.2 Accuracy
If field or laboratory contamination exists, the impact on the data will be evaluated during the
data usability assessment. The direction of bias for contamination will be identified.