Ambient Air Monitoring Program Section No. 16
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 113 of 116
Accuracy is assessed by determining percent recoveries (%Rs) for surrogate/internal standard
compounds added to each field and QC sample to be analyzed for organic parameters. Accuracy
for all analyses will be further assessed through determination of %Rs for LCSs, SRMs, field
spikes, and calibration results, etc. If the Data Validation memoranda indicate contamination
and/or analytical biases, the impact on the data will be assessed.
%R for LCSs, SRMs, field spikes, and surrogate compound results will be determined according
to the following equation:
„ Experimental Concentration ,
%R = —------------------------------a: 100
Known Amount Added
Overall contamination and accuracy^ias will be reviewed for each analytical parameter. The
data usability assessment will include any limitations on the use of the data, if it is limited to a
particular data set, parameter, or laboratoiy. If the accuracy results yield data which are not
usable, the Data Validation memoranda will identify how this problem will be resolved and the
potential need for resampling will be discussed.
16.2.3 Representativeness
If field duplicates indicate spatial variability, the data usability assessment will evaluate the
impact on the data. Overall sample representativeness will be evaluated for each analytical
parameter. The data usability assessment will include any limitations on the use of the data, if
limited to a particular, data set, parameter, or laboratory. If the results of the evaluation of
representativeness yield data which are not usable, the Data Validation memoranda will identify
how this problem will be resolved and the potential need for resampling will be discussed.
16.2.4 Sensitivity and Quantitation Limits
Overall sensitivity will be reviewed for each analytical parameter. The impact on the lack of
sensitivity or the reporting of higher quantitation limits by the laboratory will be assessed. The
Data Usability Assessment will include any limitations on the use of the data, if limited to a
particular data set, parameter, or laboratory. If the results of the evaluation of sensitivity yield
data which are not usable, the Data Validation memoranda will identify how this problem will be
resolved and the potential need for resampling will be discussed.
16.2.5 Completeness
Completeness is the ratio of the number of valid sample results to the total number of samples
analyzed or processed. Following completion of the testing, the percent completeness will be
calculated by the following equation: