NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 16
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 114 of 116
, (number of valid measurements')
Completeness =---------------------------------------------- % lUL)
(number of measurements planned)
Overall completeness will be reviewed for each analytical parameter. The data usability
assessment will include any limitations on the use of the data, if limited to a particular data set,
parameter, or laboratory. If the results of the evaluation of completeness yield data which are not
usable, the Data Validation memoranda will identify how this problem will be resolved and the
potential need for resampling will be discussed.
16.2.6 Data Limitations and Actions
The field and laboratory data collected during this investigation will be used to achieve the
objectives identified in Section 8.0 of this QAPP. The QC results associated with each analytical
parameter will be compared to the objectives presented in this QAPP. Data generated in
association with QC results meeting the stated acceptance criteria (i.e., data determined to be
valid) will be considered usable for decision-making purposes. Limitations on the use of the data
will be stated and explained, if necessary.
In addition, the data obtained may be both qualitatively and quantitatively assessed on a project
wide and parameter-specific basis. Results of the measurement error assessments may be
applied against the site as a whole; any conclusions will be documented in the final report. Data
generated in associated with QC results not meeting the stated acceptance criteria may stiU be
considered usable for decision-making purposes, depending on certain factors. This assessment
will be performed by the TRC Project Manager, in conjunction with the TRC Project QA
Officer. Factors to be considered in this assessment of field and laboratory data will include, but
not necessarily be limited to, the following.
• Conformance to the field methodologies proposed in the QAPP,
• Conformance to the EPA and NIOSH methods provided in the QAPP,
• Adherence to proposed sampling slralcgy.
• Presence of elevated detection limits due to matrix interferences or contaminants present at
high concentrations,
• Presence of analytes not expected to be present,
• Conformance to validation protocols included in the QAPP for both field and laboratory data,
• Unusable data sets (qualified as “R”) based on the data validation results,
• Data sets identified as usable for limited purposes (qualified as “J”) based on the data
validation results,
• Effect of qualifiers applied as a result of data validation on the ability to achieve the project
objectives,
• Status of all issues requiring corrective action, as presented in the QA reports to
management.