Ambient Air Monitoring Program Section No. 16 Quality Assurance Project Plan Revision No.: 0 130 1 iberly Street - NY, NY Date: Augnst 2005 Lower Manhattan Development Coi-poration Page 112 of 116

All data from the Background Phase will be subjected to a limited validation, which includes, at a minimum, a completeness check, an evaluation of chain-of-custody and sample login documents, an overall evaluation of data and potential usability issues, technical holding times, and QC sample results (blanks, surrogate spikes, MS/MSDs, calibrations, matrix duplicates, and LCS, etc.). Following this, a limited validation will be performed on a subset of the data. For the first two months of the program, the validation will be performed on a weekly basis followed by a monthly basis thereafter. Completeness checks will be administered on all data to determine whether deliverables specified in the QAPP are present. The reviewer will determine whether all required items are present and will request copies of missing deliverables.

Upon completion of the validation, a report will be prepared summarizing the elements reviewed. Validated data will be used to generate tables.

16.2 Data Usability

The purpose of this section is to indicate the methods by which it will be ensured that the validated laboratory data collected for this investigation are consistent with the project quality objectives established for the project, to ensure the quality of data was sufficient for its intended use, and to identify trends, relationships, and anomalies in the data. Conclusions based on the data, limitations on the use of the data, and the determination if data gaps exist will be included in the Data Validation memoranda.

16.2.1 Precision

The RPD between the LCS and LCS duplicate or sample and sample duplicate, is calculated to compare to precision objectives. LCS/LCS duplicates and laboratory duplicates will be used to assess analytical precision and the field duplicates will be used to assess project precision. The RPD will be calculated according to the following formula:

(j^fnount in Sample 1-Amount in Sample 2') 0.5 (Amount in Sample 1 + Amount in Sample 2)

The impact of analytical imprecision, project imprecision, and overall imprecision (when both analytical and project precision tests show problems) on data usability will be assessed. If the precision results yield data which are not usable, the Data Validation memoranda will identify how this problem will be resolved and the potential need for resampling will be discussed.

16.2.2 Accuracy

If field or laboratory contamination exists, the impact on the data will be evaluated during the data usability assessment. The direction of bias for contamination will be identified.

L2005-346 Rev. 1

CITY_21MC100_003243518

NYC-WTC_000441673

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000441673Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449648

Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

Compare copies and versions →