Community Air Monitoring Chain of Custody

Machine-extracted title · confidence 50%

CoC for environmental monitoring during 133-135 Greenwich and 21-23 Thames abatement.

NYC-WTC_000425860–000425897
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part II - Environmental Community Monitoring Plan 133-135 Greenwich & 21-23 Thames Streets Airtek Project 05-0701 - Rev 2 September 16, 2005

The exposed sample filters are transported in a cooler to limit the loss of volatile material, and are then kept in a refrigerator if they are cannot be weighed within 10 days of sampling (they still must be weighed within 30 days of sampling to be valid). Unexposed filters are taken out to the site under similar controlled conditions (usually in a cooler, although this is not necessary).

• Data requirements: o Backup instruments, field staff, and supplies will be maintained throughout the monitoring duration to ensure continuous operation of monitoring stations and high data recovery. o Data quality objective: 10% coefficient of variation. The coefficient of variation, CV, is the standard deviation as a fraction of the mean: cv =^. X • Measures of Accuracy and Bias: o Check of flow rate o Audit by collocation with a portable FRM sampler. Measures of Precision: o Check of flow rate o Collocation (see below). Collocation: o Monitors have a second monitor collocated at the same site, rotated between sites. o The second ("duplicate") sampler runs every 6 days. o Collocated particulate samplers must be less than 4 m apart but more than 1 m apart.

The PM2.5 sampler requires enhanced quality control measures because of its unique design and operational attributes. Examples of these QC measures include:

• Filter equilibration temperature control of -I-/-2 °C over 24 hours • A pre-sampling filter weighing within 30 days of sampling period • Retrieving the filter from the sampler within 96 hours of collection • A post-sampling filter equilibration and re-weighing within 240 hours after the sampling period

The precision check for manual methods is based on a comparison of the concentrations measured by two samplers that collected data side-by-side during the same specific time period. To ensure that the two collocated samplers duplicate similar conditions during monitoring specific rules are enforced: The two collocated PM2.5 samplers must be within 4 meters of each other and particulate matter samplers must be at least 1 meter apart to preclude airflow interference. This 1-meter separation is based on the low volume of sampling. Currently, the PM2.5 FRM monitors have a sampling volume of 16.67 L/min. At low concentrations, agreement between the measurements of collocated samplers, since they are expressed as percent

28

CITY_DEP_WORBY_CANNATA_SUBP_000087311

NYC-WTC_000425887

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000425887Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444890

Chain-of-custody/documentation for air monitoring around 133-135 Greenwich and 21-23 Thames

Similar indexed content

Compare copies and versions →