NYC 9/11 Public Portal Document
Part II - Environmental Community Monitoring Plan
133-135 Greenwich & 21-23 Thames Streets
Airtek Project 05-0701 - Rev 2 September 16, 2005
The exposed sample filters are transported in a cooler to limit the loss of volatile material, and are
then kept in a refrigerator if they are cannot be weighed within 10 days of sampling (they still
must be weighed within 30 days of sampling to be valid). Unexposed filters are taken out to the
site under similar controlled conditions (usually in a cooler, although this is not necessary).
• Data requirements:
o Backup instruments, field staff, and supplies will be maintained
throughout the monitoring duration to ensure continuous operation of
monitoring stations and high data recovery.
o Data quality objective: 10% coefficient of variation. The coefficient of variation,
CV, is the standard deviation as a fraction of the mean:
cv =^.
X
• Measures of Accuracy and Bias:
o Check of flow rate
o Audit by collocation with a portable FRM sampler.
Measures of Precision:
o Check of flow rate
o Collocation (see below).
Collocation:
o Monitors have a second monitor collocated at the same site, rotated between
sites.
o The second ("duplicate") sampler runs every 6 days.
o Collocated particulate samplers must be less than 4 m apart but more than 1 m
apart.
The PM2.5 sampler requires enhanced quality control measures because of its unique design and
operational attributes. Examples of these QC measures include:
• Filter equilibration temperature control of -I-/-2 °C over 24 hours
• A pre-sampling filter weighing within 30 days of sampling period
• Retrieving the filter from the sampler within 96 hours of collection
• A post-sampling filter equilibration and re-weighing within 240 hours after the sampling
period
The precision check for manual methods is based on a comparison of the concentrations
measured by two samplers that collected data side-by-side during the same specific time period.
To ensure that the two collocated samplers duplicate similar conditions during monitoring
specific rules are enforced: The two collocated PM2.5 samplers must be within 4 meters of each
other and particulate matter samplers must be at least 1 meter apart to preclude airflow
interference. This 1-meter separation is based on the low volume of sampling. Currently, the
PM2.5 FRM monitors have a sampling volume of 16.67 L/min. At low concentrations, agreement
between the measurements of collocated samplers, since they are expressed as percent
28
CITY_DEP_WORBY_CANNATA_SUBP_000087311
NYC-WTC_000425887
OCR can misread numbers and units. Confirm readings against the page image before using them.