NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 33 pages

Ambient air monitoring, 130 Liberty Street, May 2005

Machine-extracted title · confidence 55%

Chain-of-custody for ambient air monitoring at 130 Liberty Street with LMDC/NYC agency info, May 2005.

NYC-WTC_000424950–000424982
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

5.0 SAMPLING AND ANALYSES METHODOLOGY A summary of all sampling and analyses methods proposed for use during the deconstruction of 130 Liberty Street is provided in Table 2. All analytes will be measured at each of the seven (7) stations identified in Section 2.0 of this plan during all three (3) of the program phases. These phases as defined in Section 3.0 of this plan include background monitoring (2 weeks prior to Phase I), Phase I - Asbestos and COPC Abatement, and Phase II - Structural Deconstruction. As noted, all samples in Table 2 will be collected over 24-hour integrated time periods with the exception of asbestos, PMio and mercury vapor employing the Lumex device. Asbestos samples will be collected over 4-12 hour averaging periods, while PMio measurements will be collected on a continuous near “real time” basis. Proper chain of custody procedures will be employed for all intregrated samples collected. Details regarding the sampling and analyses methods planned for each type of target parameter is provided in the following sections.

Table 2. Summary of Sampling and Analyses Methods Sample Duration Per Analyte Sampling Method Comments Rate* day Metals Antimony, Barium, TSP High Volume Air 10001pm 24 hours XRay-Fluoresence (XRF) Beryllium, Cadmium, Sampler 40 CFR Part EPA Metliod IO 3.3 Chromium, Copper, 50 App B Eead, Manganese, Nickel, and Zinc Mercury (Gas) Ohio Lumex RA 915-1- 20 1pm Instantaneously Elemental (gas) Mercury Direct Read Analysis Mercury (Total) lodated Carbon Trap 4 1pm 24 hours with eVAE Particulate and Dust Asbestos NIOSII 7402 2-6 1pm Minimum of 4 Analysis via AIIERA Mod. hours Methodology Particulate PMio Met One EBAM 16.7 1pm 24 hours Respirable Crystalline NIOSH 0600/7500 2.5 1pm 24 hours SKC Aluminum Cyclone Silica and Dust Organics (semivolatile) Dioxins/Furans EPA TO 9A 200-300 1pm 24 hours Quartz Fiber Filter and PUF (PCDDs/PCDFs) Cartridge Polychlorinated EPA TO 4A 200-300 1pm 24 hours Quartz Fiber Filter and PUF biphenyls (PCB) Caihidge Polycyclic Aromatic EPATO 13A 200-300 1pm 24 hours Quartz Fiber Filter and Hydrocarbons (PAH) PUE/XAD-2 “Sandwich” Cartridge *lpm = tilers per minute

L2005-149 (051205) 1 5023623.2

CITY_DEP_WORBY_CANNATA_SUBP_000077398

NYC-WTC_000424962

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424962Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427190

Chain-of-custody for August 2005 ambient air monitoring at 130 Liberty Street deconstruction site, LMDC.

Similar indexed content

Compare copies and versions →