NYC 9/11 Public Portal Document
5.0 SAMPLING AND ANALYSES METHODOLOGY
A summary of all sampling and analyses methods proposed for use during the deconstruction of
130 Liberty Street is provided in Table 2. All analytes will be measured at each of the seven (7)
stations identified in Section 2.0 of this plan during all three (3) of the program phases. These
phases as defined in Section 3.0 of this plan include background monitoring (2 weeks prior to
Phase I), Phase I - Asbestos and COPC Abatement, and Phase II - Structural Deconstruction. As
noted, all samples in Table 2 will be collected over 24-hour integrated time periods with the
exception of asbestos, PMio and mercury vapor employing the Lumex device. Asbestos samples
will be collected over 4-12 hour averaging periods, while PMio measurements will be collected
on a continuous near “real time” basis. Proper chain of custody procedures will be employed for
all intregrated samples collected. Details regarding the sampling and analyses methods planned
for each type of target parameter is provided in the following sections.
Table 2. Summary of Sampling and Analyses Methods
Sample Duration Per
Analyte Sampling Method Comments
Rate* day
Metals
Antimony, Barium, TSP High Volume Air 10001pm 24 hours XRay-Fluoresence (XRF)
Beryllium, Cadmium, Sampler 40 CFR Part EPA Metliod IO 3.3
Chromium, Copper, 50 App B
Eead, Manganese,
Nickel, and Zinc
Mercury (Gas) Ohio Lumex RA 915-1- 20 1pm Instantaneously Elemental (gas) Mercury
Direct Read Analysis
Mercury (Total) lodated Carbon Trap 4 1pm 24 hours
with eVAE
Particulate and Dust
Asbestos NIOSII 7402 2-6 1pm Minimum of 4 Analysis via AIIERA Mod.
hours Methodology
Particulate PMio Met One EBAM 16.7 1pm 24 hours
Respirable Crystalline NIOSH 0600/7500 2.5 1pm 24 hours SKC Aluminum Cyclone
Silica and Dust
Organics (semivolatile)
Dioxins/Furans EPA TO 9A 200-300 1pm 24 hours Quartz Fiber Filter and PUF
(PCDDs/PCDFs) Cartridge
Polychlorinated EPA TO 4A 200-300 1pm 24 hours Quartz Fiber Filter and PUF
biphenyls (PCB) Caihidge
Polycyclic Aromatic EPATO 13A 200-300 1pm 24 hours Quartz Fiber Filter and
Hydrocarbons (PAH) PUE/XAD-2 “Sandwich”
Cartridge
*lpm = tilers per minute
L2005-149 (051205) 1 5023623.2