4.0 TARGET PARAMETERS/COPCs
In February 2002, a multi-agency task force headed by the USEPA was formed to evaluate
indoor environments for the presence of contaminants related to the WTC terrorist attacks that
might pose long-term health risks to local residents. As part of this evaluation, a task force sub
committee was established to identify Contaminants of Potential Concern (COPC Committee)
that are likely associated with the WTC disaster and establish health-based benchmarks for those
contaminants in support of planned residential cleanup efforts in Eower Manhattan.
In addition^ a number of other studies conducted by USEPA (EPA/600/R-03/142 December
2003) and (work perfonued by Eouis Berger Group) were examined as a means of establishing a
listing of target parameters appropriate to satisfy the purpose and objectives of the current
deconstruction project. These objectives include active real time monitoring of fugitive dusts
potentially related to the deconstruction as well as identifying levels of COPCS associated with
the materials at 130 Eiberty. In this manner the deconstruction project can proceed while
providing an ample margin of safety for human health and the environment in the vicinity of the
project site.
Most recently, USEPA approved an air monitoring program for use during the deconstruction of
4 Albany Street, another building contaminated by WTC dust as a result of the WTC disaster.
This Plan entitled “Specifications for Community Environmental Air Monitoring During the
Abatement and Demolition of 4 Albany Street” was issued as approved for use by USEPA and
NYDEC on December 22, 2004. The target parameters identified for monitoring during this
abatement and demolition program were also considered in the course of developing the list of
target parameters for the 130 Eiberty Street property.
Based upon these criteria the following target parameters were selected for inclusion in the
monitoring program:
• PMio-Respirable Particulate
• Asbestos
• Crystalline Silica
• PCDDs/PCDFs
• PAHs
• PCBs
• Metals (antimony, barium, beryllium, cadmium, chromium, copper, lead, mercury (gaseous
and particulate bound) manganese, nickel and zinc).
L2005-149 (051205) 1 5023623.2
CITY_DEP_WORBY_CANNATA_SUBP_000077397
NYC-WTC_000424961
OCR can misread numbers and units. Confirm readings against the page image before using them.