8.0 ACTION LEVELS AND MITIGATION MEASURES
A two tiered system will be in place during the entire term of the deconstruction project. This
system includes use of both Target Air Quality Levels and USEPA Site Specific Trigger Levels
for each of the target parameters identified previously in Section 4. A summary listing of these
Action Levels provided on a parameter specific basis is shown in Table 5.
Table 5. Target Air Quality Levels and USEPA Site Trigger Levels^*
USEPA Site Specific
Analyte Target Air Quality Levels Trigger Levels
Metals
Antimony 5 ug/m^ 14 Ug/m'
Barium 5 ug/m 5 ug/m'
Beryllium 0.02 ug/m^ 0.2 ug/m'
Cadmium 0.04 ug/m^ 2 ug/m'
Chromium 0.6 ug/m' 60 ug/m'
Copper 10 ug/m^ 100 ug/m'
Lead 1.5 ug/m' 5 ug/m'
Manganese 0.5 ug/m' 0.5 ug/m'
Mercury 0.3 ug/m' 3 ug/m'
Nickel 0.2 ug/m' 28 ug/m'
Zinc 16 ug/m' 160 ug/m'
Particles and Dust
Asbestos 0.0009 f/cc (PCMe fibers) 70 S/mm' (TEM AHERA
structures)
Particulate PM^q (24 hour average) 150 ug/m' _______ 150 ng/m'______
Respirable Silica (crystalline) 10 ug/m^ lOug/m^
Organics (semi-volatiles)
Dioxins/Furans (2,3,7,8 - TCDD equiv.) 0.00025 ng/m 0.025 ng/m^
PCB (total Aroclors)_________________ 0.12 ug/m^ 12ug/m^
PAH (benzo-a-pyrene equivalent) 0.034 ug/nr 3.4ug/n?
'‘All values listed in Table 5 are consistent with Target Air Quality Levels and USEPA Site Trigger Levels adopted for use during 4 Albany Street
deconstruction project. As such these levels represent USEPA/NYDEC sanctioned values.
8.1 Action Levels
The following actions will be taken if there is an exceedance of any Target Air Quality Level. If
there is an exceedance of both the Target Air Quality Level and USEPA Site Specific Trigger
Level, actions associated with the USEPA Site Specific Trigger Level will govern.
8.1.1 Target Air Quality Levels
Any 24-hour PMio value in excess of the Target Air Quality Level will be considered an
“exceedance” and the actions described below will be taken.