5.0 SAMPLING AND ANALYSES METHODOLOGY
A summary of all sampling and analyses methods proposed for use during the deconstruction of
130 Liberty Street is provided in Table 2. All analytes will be measured at each of the seven (7)
stations identified in Section 2.0 of this plan during all three (3) of the program phases. These
phases as defined in Section 3.0 of this plan include background monitoring (2 weeks prior to
Phase I), Phase I - Asbestos and COPC Abatement, and Phase II - Structural Deconstruction. As
noted, all samples in Table 2 will be collected over 24-hour integrated time periods with the
exception of asbestos, PMw and mercury vapor employing the Lumex device. Asbestos samples
will be collected over 4-12 hour averaging periods, while PMw measurements will be collected
on a continuous near “real time” basis. Proper chain of custody procedures will be employed for
all intregrated samples collected. Details regarding the sampling and analyses methods planned
for each type of target parameter is provided in the following sections.
Table 2. Summary of Sampling and Analyses Methods
Sample Duration Per
Analyte Sampling Method Comments
Rate* day
Metals
Antimony, Barium, TSP High Volume Air 1000 1pm 24 hours XRay-Eluoresence (XRF)
Beryllium, Cadmium, Sampler 40 CFR Part EPA Metliod IO 3.3
Chromium, Copper, 50 App B
Lead, Manganese,
Nickel, and Zinc
Mercury (Gas) Ohio Lumex RA 915-1- 201pm Instantaneously Elemental (gas) Mercury
Direct Read Analysis
Mercury (Total) lodated Carbon Trap 4 1pm 24 hours
with eVAF
Particulate and Dust
Asbestos NIOSH 7402 2-6 1pm Minimum of 4 Analysis via AHERA Mod.
hours Methodology
Particulate PMio Met One EBAM 16.7 1pm 24 hours
Respirable Ciystalline NIOSH 0600/7500 2.5 1pm 24 hours SKC Aluminum Cyclone
Silica and Dust
Organics (semivolatile)
Dioxins/Furans EPA TO 9A 200-300 1pm 24 hours Quartz Fiber Filter and PUF
(PCDDs/PCDFs) Cartridge
Polychlorinated EPA TO 4A 200-300 1pm 24 hours Quartz Fiber Filter and PUF
biphenyls (PCB) Cartridge
Polycyclic Aromatic EPATO 13A 200-300 1pm 24 hours Quartz Fiber Filter and
Hydrocarbons (PAH) PUF/XAD-2 “Sandwich”
Cartridge
*lpm = liters per minute
L2005-149(051205) 1 5023623.2
CITY_21MC100_0 02652322
NYC-WTC_000447738
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000447738Source: NYC Law Department, mirrored locally