Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
Table 7-2. Phase I: Preparation Phase & Asbestos and COPC Abatement and Removal
Sampling and Analysis Summary
Location Parameter(s) Sample Frequency Analysis Method
Site Area Mercury (vapor/gas) Each Day Lumex, portable
mercurys analyzer
Site Area Visible dust emissions Each Day Visual observation
Scaffolding/Street 1. Asbestos Each Day (asbestos and silica 1. TEM/SEM
Level/School Auditorium 2. Silica are sampled during work shift 2.XRD
Roof (3 Locations)
3. Metals Each Day (24 hr. Basis) 3. ICP/MS
4. PCDDs/PCDFs 4. HRGC/HRMS
5. PAHs 5. GC/MS
6. PCBs 6. GC/ECD
7. Mercury (total) 7. lodatedCarbon
Trap/CVAFS
8. PMio Continuously “Real-Time” Each 8. EBAM/Gravimetric
9. PM2.5 Day (PMio and PM2.5 on 24 hour 9. EBAM/Gravimetric
basis at each location; PMio and
PM2.5 reference sampler at 1
location per day on 24- hour
basis with location changed
monthly)
Table 7-3. Phase II - Structural Deconstruction Phase Sampling and Analysis Summary
Location Parameter(s) Sample Frequency Analysis Method
Site Area Mercury (vapor/gas) Each Day Lumex, portable
mercury analyzer
Site Area Visible dust emissions Each Day Visual observation
Scaffolding/Street 1. Asbestos Each Day (asbestos and silica 1. TEM/SEM
Level/School Auditorium 2. Silica are sampled during work shill 2.XRD
Roof (3 Locations)
3. Metals Each Day (24 hr. Basis) 3. ICP/MS
4. PCDDs/PCDFs 4. HRGC/HRMS
5. PAHs 5. GC/MS
6. PCBs 6. GC/ECD
7. Mercury (total) 7. lodatedCarbon
Trap/CVAFS
8. PMio Continuously “Real-Time” Each 8. EBAM/Gravimetric
9. PM2.5 Day (PMio and PM2.5 on 24 hour 9. EBAM/Gravimetric
basis at each location; PMio and
PM2.5 reference sampler at 1
location per day on 24- hour
basis with location changed
monthly)