Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
Table 7-2. Abatement Phase: Asbestos and COPC Abatement and Removal Sampling and
Analysis Summary
Location Parameter(s) Sample Frequency Analysis Method
Site Area Mercury (vapor/gas) Each Day Lumex, portable
mercLiry analyzer
Site Area Visible dust emissions Each Day Visual observation
Scaffolding/Street 1. Asbestos Each Day (asbestos and silica 1. TEM/SEM
Level/School Auditorium 2. Silica are sampled during work shift 2.XRD
Roof (3 Locations)
3. Metals Each Day (24 hr. Basis) 3. ICP/MS
4. PCDDs/PCDFs 4. HRGC/HRMS
5. PAHs 5. GC/MS
6. PCBs 6. GC/ECD
7. Mercury (total) 7. lodatedCarbon
Trap/eVAFS
8. PMio Continuously “Real-Time” Each 8. EBAM/Gravimetric
9. PM2.5 Day (PMio and PM2.5 on 24 hour 9. EBAM/Gravimetric
basis at each location; PMio and
PM2.5 reference sampler at 1
location per day on 24- hour
basis with location changed bi
weekly)
Table 7-3. Demolition Phase - Structural Deconstruction Phase Sampling and Analysis
Summary
Location Paranieter(s) Sample Frequency Analysis Method
Site Area Mercury (vapor/gas) Each Day Lumex, portable
mercury analyzer
Site Area Visible dust emissions Each Day Visual observation
Scaffolding/Street 1. Asbestos Each Day (asbestos and silica 1. TEM/SEM
Level/School Auditorium 2. Silica are sampled during work shift 2.XRD
Roof (3 Locations)
3. Metals Each Day (24 hr. Basis) 3. ICP/MS
4. PCDDs/PCDFs 4. HRCiC/HRMS
5. PAHs 5. GC/MS
6. PCBs 6. GC/ECD
7. Mercury (total) 7. lodatedCarbon
Trap/eVAFS
8. PMio Continuously “Real-Time” Each 8. EBAM/Gravimetric
9. PM2.5 Day (PMio and PM2.5 on 24 hour 9. EBAM/Gravimetric
basis at each location; PMio and
PM2.5 reference sampler at 1
location per day on 24- hour
basis with location changed bi
weekly)
29
CITY_DEP_WORBY_CANNATA_SUBP_000072569
NYC-WTC_000424351
OCR can misread numbers and units. Confirm readings against the page image before using them.